Lower-temperature pH sensitivity

At 32 °C and 22 bar(a), a wetted line sees 3 mol% CO₂. A 30% net pH credit is entered for sensitivity.

Inputs

SI units

Use absolute pressure and the gas-phase mole fraction. Enter a single measured or assumed net mitigation efficiency.

°C
bar(a)
%
mm/yr
% Enter one independently justified net efficiency.
Mitigated rate
0.792 mm/yr
Baseline rate
1.131 mm/yr
CO₂ partial
0.66 bar(a)
CO₂ fugacity
0.612 bar(a)

Gas, wet steel and mitigation boundary

Schematic
Gas, wet steel and mitigation boundary (schematic, not to scale)CO₂ gasWater-wet carbon steelWet steel boundaryNet credit shown in cyanCO₂ PARTIAL0.66 bar(a)FUGACITY0.612 bar(a)MITIGATED RATE0.792 mm/yr
Above modeled rate target

Screening for water-wet carbon steel. Confirm water chemistry, phase wetting, corrosion data and sustained mitigation performance.

Mitigated rate ÷ selected screening target

Calculation details

Absolute temperature
305.15 K
Partial pressure
0.66 bar(a)
Fugacity coefficient
0.9274
Corrected CO₂ fugacity
0.6121 bar(a)
Remaining modeled rate fraction
70 %
Modeled rate reduction
0.339 mm/yr
Mitigated metric rate
0.79152 mm/yr
Mitigated US rate
31.162 mpy

Worked calculation

Starting values · SI
  1. The gas fraction gives 0.66 bar(a) partial pressure. The fugacity coefficient is 0.9274.
  2. The calculated CO₂ fugacity is 0.61208 bar(a) and the baseline rate is 1.13074 mm/yr.
  3. The 30% net efficiency gives 0.79152 mm/yr, or 31.16202 mpy.

The credit is a user assumption. Validate it with the measured water chemistry or a corrosion model that includes pH.

Method and limits

  1. Find CO₂ partial pressure

    Multiply absolute pressure in bar by the gas-phase CO₂ mole fraction. Convert temperature to kelvin before evaluating either equation.

  2. Correct for fugacity

    log₁₀(a) = (0.0031 − 1.4/T_K) × P_bar. The fugacity f is a × P_CO₂. The uninhibited rate is 10^[5.8 − 1710/T_K + 0.67 log₁₀(f)] in mm/yr. Zero CO₂ gives a zero term directly.

  3. Apply the chosen net credit

    Multiply by (1 − η), where η is the credited efficiency fraction for a pH effect, protective scale, inhibitor or their measured combined effect. Convert mm/yr to mpy by dividing by 0.0254.