PREN and Galvanic Area Ratio Calculator
Compare stainless, duplex and nickel alloy composition and see how an exposed cathode-to-anode area ratio changes a rate proxy.
Inputs
SI unitsEnter mass percent from the material certificate and the wetted areas exposed to the same electrolyte. Presets are typical chemistry.
- PREN
- 34.95
- PREN with W
- 34.95
- Area factor
- 4 ×
- Rate proxy
- 0.48 mm/yr
Pitting resistance and exposed areas
SchematicArea ratio is a sensitivity screen. Check the galvanic series, electrolyte, temperature, crevices and actual alloy condition.
Calculation details
- Standard PREN tier
- 32 to 40 · higher resistance
- Tungsten-adjusted tier
- 32 to 40 · higher resistance
- Galvanic area screen
- Raised area contrast
- Area-scaled anode rate
- 0.48 mm/yr
Inputs used
- Alloy composition preset
- 2205 duplex
- Chromium · Cr
- 22 %
- Molybdenum · Mo
- 3.1 %
- Tungsten · W
- 0 %
- Nitrogen · N
- 0.17 %
- Cathode / anode area
- 4 ×
- Uncoupled anode rate
- 0.12 mm/yr
Method and limits
Calculate each composition index
Standard PREN = Cr + 3.3Mo + 16N. With tungsten use PREN_W = Cr + 3.3(Mo + 0.5W) + 16N. Enter each element in mass percent.
Read the comparison bands
The bands are below 25, 25 to below 32, 32 to 40 inclusive, and above 40. The highest band denotes a seawater candidate for further assessment.
Compare the exposed areas
The proxy multiplies the uncoupled anode rate by max(1, cathode/anode area). Area contrast is low up to 1, raised above 1 through 10, and high above 10. These are comparison bands for the area effect.