ASME B30.5 · ASCE 7 context

Cylindrical vessel wind drag

A 22 metric t vessel presents 36 m² to a 9 m/s gust under the selected cylinder drag assumption.

Inputs

Suspended load and profile
metric t
m²
m
Gust and cutoff
m/s
m/s
m/s
kg/m³
Back to results ↑

Results

Static screeningEdit inputs ↓
Suspended-load pendulumSAIL AREA25.2m²SIDE FORCE1.25kNSWAY ANGLE0.33°GUST MARGIN2m/sHOOKPLUMBφ 0.33°Side forceGust speed limit81.82%Suspended loadWind forceGravity referenceLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results
  • Generic drag coefficient selected. Verify projected orientation and drag factor for the load.
Effective sail area, Cd × A
25.2 m²
Horizontal wind force
1.25 kN
Equilibrium swing angle
0.33 °
Gust margin to cutoff
2 m/s
Dynamic wind pressure
0.05 kPa
Static horizontal offset
0.1 m
Lower OEM or site gust limit
11 m/s

Use projected area normal to the wind, then compare with the lower of the configuration-specific and site cutoffs.

Effective sail area, Cd × A 25.2 m² · Horizontal wind force 1.25 kN

Dynamic pressure

q = ½ρV² ≈ 0.00256 Vmph² psf

The US approximation assumes standard sea-level density. The calculator uses the entered density in both unit systems.

Sail force and deflection

Fw = q × Cd × A; φ = atan(Fw/W)

Use the largest projected area in the lift orientation. The idealized static offset is line length × sin φ.

Wind headroom

Margin = min(OEM limit, site limit) − gust

Use the limits for the actual crane configuration and load sail area.

Estimate steady payload drag only. Use the crane manufacturer’s instructions and load-specific wind limit. This model excludes transient motion, the boom’s own wind loading and ASCE 7 exposure and gust factors.

Other worked examples