Dynamic pressure
q = ½ρV² ≈ 0.00256 Vmph² psf
The US approximation assumes standard sea-level density. The calculator uses the entered density in both unit systems.
ASME B30.5 · ASCE 7 context
A truss has 240 ft² of projected exposed members in the controlling orientation. The hook line is 85 ft long.
Schematic geometry. Margin bars mark 100% of the entered limit.
Use a reviewed net area and a suitable drag factor. A small angle can still produce noticeable offset on a long line.
Effective sail area, Cd × A 384 ft² · Horizontal wind force 283.71 lbf
q = ½ρV² ≈ 0.00256 Vmph² psf
The US approximation assumes standard sea-level density. The calculator uses the entered density in both unit systems.
Fw = q × Cd × A; φ = atan(Fw/W)
Use the largest projected area in the lift orientation. The idealized static offset is line length × sin φ.
Margin = min(OEM limit, site limit) − gust
Use the limits for the actual crane configuration and load sail area.
Estimate steady payload drag only. Use the crane manufacturer’s instructions and load-specific wind limit. This model excludes transient motion, the boom’s own wind loading and ASCE 7 exposure and gust factors.
CraneRiggingLab · Lift screening worksheet
ASME B30.5 · ASCE 7 context · US · lb
Screening estimates only. Have a qualified rigger and a professional engineer (PE), where required, review the lift plan. Use the OEM chart for the actual configuration.
Estimate steady payload drag only. Use the crane manufacturer’s instructions and load-specific wind limit. This model excludes transient motion, the boom’s own wind loading and ASCE 7 exposure and gust factors.