Dynamic pressure
q = ½ρV² ≈ 0.00256 Vmph² psf
The US approximation assumes standard sea-level density. The calculator uses the entered density in both unit systems.
ASME B30.5 · ASCE 7 context
A 1,950 kg enclosure presents an exposed face of 54 m² during a 12 m/s gust. The reviewed drag coefficient is 1.9.
Schematic geometry. Margin bars mark 100% of the entered limit.
A low load weight relative to drag increases sway. Review the conservative path envelope and the crane’s sail-area rules.
Effective sail area, Cd × A 102.6 m² · Horizontal wind force 9.38 kN
q = ½ρV² ≈ 0.00256 Vmph² psf
The US approximation assumes standard sea-level density. The calculator uses the entered density in both unit systems.
Fw = q × Cd × A; φ = atan(Fw/W)
Use the largest projected area in the lift orientation. The idealized static offset is line length × sin φ.
Margin = min(OEM limit, site limit) − gust
Use the limits for the actual crane configuration and load sail area.
Estimate steady payload drag only. Use the crane manufacturer’s instructions and load-specific wind limit. This model excludes transient motion, the boom’s own wind loading and ASCE 7 exposure and gust factors.
CraneRiggingLab · Lift screening worksheet
ASME B30.5 · ASCE 7 context · SI · kg
Screening estimates only. Have a qualified rigger and a professional engineer (PE), where required, review the lift plan. Use the OEM chart for the actual configuration.
Estimate steady payload drag only. Use the crane manufacturer’s instructions and load-specific wind limit. This model excludes transient motion, the boom’s own wind loading and ASCE 7 exposure and gust factors.