ASME B30.5 · ASCE 7 context

Open lattice frame with net projected area

A truss has 240 ft² of projected exposed members in the controlling orientation. The hook line is 85 ft long.

Inputs

Suspended load and profile
lb
ft²
ft
Gust and cutoff
mph
mph
mph
slug/ft³
Back to results ↑

Results

Static screeningEdit inputs ↓
Suspended-load pendulumSAIL AREA384ft²SIDE FORCE283.71lbfSWAY ANGLE1.12°GUST MARGIN8mphHOOKPLUMBφ 1.12°Side forceGust speed limit68%Suspended loadWind forceGravity referenceLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results
  • Generic drag coefficient selected. Verify projected orientation and drag factor for the load.
Effective sail area, Cd × A
384 ft²
Horizontal wind force
283.71 lbf
Equilibrium swing angle
1.12 °
Gust margin to cutoff
8 mph
Dynamic wind pressure
0.74 psf
Static horizontal offset
1.66 ft
Lower OEM or site gust limit
25 mph

Use a reviewed net area and a suitable drag factor. A small angle can still produce noticeable offset on a long line.

Effective sail area, Cd × A 384 ft² · Horizontal wind force 283.71 lbf

Dynamic pressure

q = ½ρV² ≈ 0.00256 Vmph² psf

The US approximation assumes standard sea-level density. The calculator uses the entered density in both unit systems.

Sail force and deflection

Fw = q × Cd × A; φ = atan(Fw/W)

Use the largest projected area in the lift orientation. The idealized static offset is line length × sin φ.

Wind headroom

Margin = min(OEM limit, site limit) − gust

Use the limits for the actual crane configuration and load sail area.

Estimate steady payload drag only. Use the crane manufacturer’s instructions and load-specific wind limit. This model excludes transient motion, the boom’s own wind loading and ASCE 7 exposure and gust factors.

Other worked examples