ASME B30.9 · Planar statics

One sling measured too long

Two measured legs meet above an 11,000 lb pump, but their intersection is 7.2 in to the right of the CG.

Inputs

Load and tolerance
lb
in
Left pickup A
ft
ft
ft
Right pickup B
ft
ft
ft
Back to results ↑

Results

Static screeningEdit inputs ↓
Pickup geometry and center of gravityTENSION A—TENSION B—INWARD FORCE—HOOK OFFSET7.2inCG PLUMBABPICKUP SPANd₁d₂Plumb tolerance720%Left lineRight lineCG projectionLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Review required
  • The measured rigging cannot hold the entered attitude within the plumb screen. Leg forces are withheld.
Left sling tension
—
Right sling tension
—
Inward force per pickup
—
Measured hook offset, + toward B
7.2 in
Left angle from horizontal
—
Right angle from horizontal
—
Measured hook height above CG
8 ft

Compare the measured offset with the selected tolerance. Leg forces are withheld until the proposed hanging attitude can balance.

Measured hook offset, + toward B 7.2 in

Locate the hook

H lies on both sling-length circles

Circle centers are the two pickups. Select the upper intersection above both pickups and measure its horizontal offset from the CG.

Resolve the leg forces

R = W / (tan θ₁ + tan θ₂)

At the plumb target, each sling carries the same horizontal component R. The vertical components follow from the individual slopes.

Get each tension

Tᵢ = R / cos θᵢ

Angled tensions are based on the mean of the two target hook elevations within the entered plumb tolerance.

Four vertical pickups

ΣR = W; right pair = Wx/B; far pair = Wy/L

Use a level rectangle and vertical, tension-only lines. Force and moment balance bound each corner reaction. A unique four-leg share needs stiffness, stretch and compatibility or an engineered equalizer.

For two angled legs, use one plane and the declared attitude. The four-pickup bounds apply to vertical reactions on a level rectangle. The individual maxima are separate equilibrium cases. Verify line geometry, load stability, pickup strength and tagged WLL with a qualified rigger.

Other worked examples