Locate the hook
H lies on both sling-length circles
Circle centers are the two pickups. Select the upper intersection above both pickups and measure its horizontal offset from the CG.
ASME B30.9 · Planar statics
The two legs on a 9,600 lb enclosure imply a hook 0.24 in left of the measured CG. The screening tolerance is 0.5 in.
Schematic geometry. Margin bars mark 100% of the entered limit.
Compare these results with the approved equipment and lift plan.
The outputs are forces at the nearby plumb target. Treat the measured offset as uncertainty in the lift geometry.
Left sling tension 7,450.85 lbf · Right sling tension 5,120.51 lbf
H lies on both sling-length circles
Circle centers are the two pickups. Select the upper intersection above both pickups and measure its horizontal offset from the CG.
R = W / (tan θ₁ + tan θ₂)
At the plumb target, each sling carries the same horizontal component R. The vertical components follow from the individual slopes.
Tᵢ = R / cos θᵢ
Angled tensions are based on the mean of the two target hook elevations within the entered plumb tolerance.
ΣR = W; right pair = Wx/B; far pair = Wy/L
Use a level rectangle and vertical, tension-only lines. Force and moment balance bound each corner reaction. A unique four-leg share needs stiffness, stretch and compatibility or an engineered equalizer.
For two angled legs, use one plane and the declared attitude. The four-pickup bounds apply to vertical reactions on a level rectangle. The individual maxima are separate equilibrium cases. Verify line geometry, load stability, pickup strength and tagged WLL with a qualified rigger.
CraneRiggingLab · Lift screening worksheet
ASME B30.9 · Planar statics · US · lb
Screening estimates only. Have a qualified rigger and a professional engineer (PE), where required, review the lift plan. Use the OEM chart for the actual configuration.
For two angled legs, use one plane and the declared attitude. The four-pickup bounds apply to vertical reactions on a level rectangle. The individual maxima are separate equilibrium cases. Verify line geometry, load stability, pickup strength and tagged WLL with a qualified rigger.