ASME B30.9 · Planar statics

Mill housing with the CG near one pickup

A mill housing weighs 24 metric t. The CG is close to pickup A and one sling is nearly vertical.

Inputs

Load and tolerance
metric t
mm
Left pickup A
m
m
m
Right pickup B
m
m
m
Back to results ↑

Results

Static screeningEdit inputs ↓
Pickup geometry and center of gravityTENSION A207.54kNTENSION B40.86kNINWARD FORCE28.04kNHOOK OFFSET0mmCG PLUMBABPICKUP SPANd₁d₂Plumb tolerance0%Left lineRight lineCG projectionLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results

Compare these results with the approved equipment and lift plan.

Left sling tension
207.54 kN
Right sling tension
40.86 kN
Inward force per pickup
28.04 kN
Measured hook offset, + toward B
0 mm
Left angle from horizontal
82.23 °
Right angle from horizontal
46.67 °
Measured hook height above CG
3.66 m

Follow the plumb line and check the larger individual leg force. The weight split for a centered lift would miss the offset.

Left sling tension 207.54 kN · Right sling tension 40.86 kN

Locate the hook

H lies on both sling-length circles

Circle centers are the two pickups. Select the upper intersection above both pickups and measure its horizontal offset from the CG.

Resolve the leg forces

R = W / (tan θ₁ + tan θ₂)

At the plumb target, each sling carries the same horizontal component R. The vertical components follow from the individual slopes.

Get each tension

Tᵢ = R / cos θᵢ

Angled tensions are based on the mean of the two target hook elevations within the entered plumb tolerance.

Four vertical pickups

ΣR = W; right pair = Wx/B; far pair = Wy/L

Use a level rectangle and vertical, tension-only lines. Force and moment balance bound each corner reaction. A unique four-leg share needs stiffness, stretch and compatibility or an engineered equalizer.

For two angled legs, use one plane and the declared attitude. The four-pickup bounds apply to vertical reactions on a level rectangle. The individual maxima are separate equilibrium cases. Verify line geometry, load stability, pickup strength and tagged WLL with a qualified rigger.