OSHA 1926.1432 · Multiple cranes

Tandem equipment pick with CG near hook B

A 60 US ton equipment frame has its CG 18 ft from A and 3 ft from B. The smaller crane is supporting the far end.

Inputs

Payload and beam
US ton
ft
ft
US ton
%
Projected horizontal position, 0% at A and 100% at B.
Chart at worst lift position
US ton
US ton
US ton
US ton
Back to results ↑

Results

Static screeningEdit inputs ↓
Dual-hook free-body sketchCRANE A LOAD9.87US tonCRANE B LOAD52.68US tonA CAP MARGIN13.38US tonB CAP MARGIN3.57US tonCRANE ACRANE BPAYLOAD CG / HOOK SPANA / 75% chart cap42.46%B / 75% chart cap93.65%Crane ACrane BPayload centerlineLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results

Compare these results with the approved equipment and lift plan.

Gross demand on crane A
9.87 US ton
Gross demand on crane B
52.68 US ton
Crane A margin to 75% cap
13.38 US ton
Crane B margin to 75% cap
3.57 US ton
Crane A chart capacity used
31.84 %
Crane B chart capacity used
70.24 %
Combined lifted weight
62.55 US ton

The loaded crane can approach its chart cap while the other has surplus margin. Check CG uncertainty along the full path.

Gross demand on crane A 9.87 US ton · Gross demand on crane B 52.68 US ton

Payload reactions

Wₐ = W × b/(a + b), Wᵦ = W × a/(a + b)

Use projected horizontal distances from CG to the vertical lines. For unrotated lug coordinates, rotate them to the specified attitude before resolving reactions.

Gross hook demands

Gross share = payload share + beam share + hook gear

Use the beam CG location for its share. With gross chart capacities, include each hook block and applicable chart deductions once in gear.

Screening margin

Margin = 0.75 × chart capacity − gross share

The 75% cap is this tool’s planning assumption. Site procedures and the actual OEM load chart govern.

Use the weakest chart point at each actual radius, boom configuration and set-up. A qualified person must plan the lift under OSHA 1926.1432 where it applies. This is a static snapshot for vertical lines. Review dynamic load transfer and any off-plumb line separately.