Locate the hook
H lies on both sling-length circles
Circle centers are the two pickups. Select the upper intersection above both pickups and measure its horizontal offset from the CG.
ASME B30.9 · Planar statics
A mill housing weighs 24 metric t. The CG is close to pickup A and one sling is nearly vertical.
Schematic geometry. Margin bars mark 100% of the entered limit.
Compare these results with the approved equipment and lift plan.
Follow the plumb line and check the larger individual leg force. The weight split for a centered lift would miss the offset.
Left sling tension 207.54 kN · Right sling tension 40.86 kN
H lies on both sling-length circles
Circle centers are the two pickups. Select the upper intersection above both pickups and measure its horizontal offset from the CG.
R = W / (tan θ₁ + tan θ₂)
At the plumb target, each sling carries the same horizontal component R. The vertical components follow from the individual slopes.
Tᵢ = R / cos θᵢ
Angled tensions are based on the mean of the two target hook elevations within the entered plumb tolerance.
ΣR = W; right pair = Wx/B; far pair = Wy/L
Use a level rectangle and vertical, tension-only lines. Force and moment balance bound each corner reaction. A unique four-leg share needs stiffness, stretch and compatibility or an engineered equalizer.
For two angled legs, use one plane and the declared attitude. The four-pickup bounds apply to vertical reactions on a level rectangle. The individual maxima are separate equilibrium cases. Verify line geometry, load stability, pickup strength and tagged WLL with a qualified rigger.
CraneRiggingLab · Lift screening worksheet
ASME B30.9 · Planar statics · SI · metric t
Screening estimates only. Have a qualified rigger and a professional engineer (PE), where required, review the lift plan. Use the OEM chart for the actual configuration.
For two angled legs, use one plane and the declared attitude. The four-pickup bounds apply to vertical reactions on a level rectangle. The individual maxima are separate equilibrium cases. Verify line geometry, load stability, pickup strength and tagged WLL with a qualified rigger.