ASME B30.5 · OSHA 1926.1414

Smooth drum with excessive fleet angle

A 38 in smooth drum sits 36 ft from the lead sheave. The sheave is 3 in off the drum centerline.

Inputs

Hook load and reeving
lb
lbf
Sheave and drum
in
in
:1
in
ft
in
Back to results ↑

Results

Static screeningEdit inputs ↓
Block reeving and drum leadFAST-LINE PULL7,360.75lbfROPE FACTOR10.19:1SHEAVE D/d20:1FLEET ANGLE2.92°FIXED BLOCKTRAVELING BLOCKFast lineDead endD/d 20Fleet 2.92°Rope pull limit49.07%Required / actual D/d90%Fleet angle limit194.35%Running ropeFast lineBlock centerlineLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Review required
  • The maximum fleet angle exceeds the selected drum screen.
Estimated fast-line pull
7,360.75 lbf
Available rope design factor
10.19 :1
Sheave pitch to rope diameter
20 :1
Worst drum fleet angle
2.92 °
Friction-adjusted parts
3.8
Overall reeving efficiency
95.1 %
Rope pull at entered design factor
15,000 lbf

The far edge includes half the working width plus the offset. Compare the calculated angle with 1.5°.

Estimated fast-line pull 7,360.75 lbf · Available rope design factor 10.19 :1

Effective parts

Nₑ = ηᵏ × Σ ηⁱ, i = 0 to N − 1

η is efficiency per wrap. k counts lead sheaves before the first supporting part. Fast-line pull is suspended weight divided by Nₑ.

Rope and sheave

Design factor = MBS / P; D/d = Dpitch / drope

Use the rope maker’s minimum breaking strength and the OEM’s minimum pitch-diameter ratio.

Fleet angle

β = atan((drum width/2 + |offset|) / lead)

Use the furthest first-layer winding position. Compare with 1.5° smooth or 2.0° grooved as the entered drum-type screen.

Compare line pull with the OEM winch rating at the working drum layer and confirm compatible reeving, rope construction, termination efficiency and sheave sizing. A 3.5:1 design factor requires equipment- and use-specific review under the applicable OSHA provisions.