ASME B30.5 · OSHA 1926.1414

Wire Rope Reeving & Fleet Angle

Estimate fast-line pull from the number of supporting parts and accumulated sheave losses. Check the rope design factor, D/d and fleet angle.

Inputs

Hook load and reeving
lb
lbf
Sheave and drum
in
in
:1
in
ft
in
Back to results ↑

Results

Static screeningEdit inputs ↓
Block reeving and drum leadFAST-LINE PULL11,620.17lbfROPE FACTOR6.45:1SHEAVE D/d20:1FLEET ANGLE1.27°FIXED BLOCKTRAVELING BLOCKFast lineDead endD/d 20Fleet 1.27°Rope pull limit77.47%Required / actual D/d90%Fleet angle limit63.65%Running ropeFast lineBlock centerlineLift screening only · verify with rigger / PE and OEM chart

Schematic geometry. Margin bars mark 100% of the entered limit.

Screening results

Compare these results with the approved equipment and lift plan.

Estimated fast-line pull
11,620.17 lbf
Available rope design factor
6.45 :1
Sheave pitch to rope diameter
20 :1
Worst drum fleet angle
1.27 °
Friction-adjusted parts
5.59
Overall reeving efficiency
93.23 %
Rope pull at entered design factor
15,000 lbf

Effective parts

Nₑ = ηᵏ × Σ ηⁱ, i = 0 to N − 1

η is efficiency per wrap. k counts lead sheaves before the first supporting part. Fast-line pull is suspended weight divided by Nₑ.

Rope and sheave

Design factor = MBS / P; D/d = Dpitch / drope

Use the rope maker’s minimum breaking strength and the OEM’s minimum pitch-diameter ratio.

Fleet angle

β = atan((drum width/2 + |offset|) / lead)

Use the furthest first-layer winding position. Compare with 1.5° smooth or 2.0° grooved as the entered drum-type screen.

Compare line pull with the OEM winch rating at the working drum layer and confirm compatible reeving, rope construction, termination efficiency and sheave sizing. A 3.5:1 design factor requires equipment- and use-specific review under the applicable OSHA provisions.

Worked examples