DistillColumnLab
Menu

Worked example · Flash equilibrium

Flash just above the bubble endpoint

Solve a four-component vapor–liquid split and size a vertical drum from gas load and liquid surge.

With K-values of 2 and 0.5, raise the light component just above its bubble-point feed composition.

Vapor V/F
2.000e-5 %
Drum ID
0.9354 m
T/T height
2.806 m
Mass error
0 %

Vertical flash drum and mist eliminator

Live schematic
Flash drum with demister, vapor outlet and liquid surge regionFLASH FEED5,400 kg/hVAPOR SHARE2.00e-5 %VAPOR1.59e-4 Am³/hMIST PADT/T HEIGHT2.81 mLIQUID SURGE0.643 m³ID 0.935 m
Two phase

Screen against the gas velocity limit and a liquid surge depth of one shell diameter.

Highest gas velocity or surge-depth approach100 %
Review marker 85 % Screen limit 100 %

Worked solution

  1. Establish the phase state

    Normalize the feed. Σ zK = 1 and Σ z/K = 1.5. The equilibrium result is two phase at V/F = 2.000e-5 %.

  2. Close the phase balances

    The phase compositions and component molecular weights give 9.855e-4 kg/h vapor and 5,400 kg/h liquid. The relative mass imbalance is 0 %.

  3. Size the drum

    The gas-area ID is 2.515e-4 m and the surge ID is 0.9354 m. At the checked ID, two diameters plus surge depth give a T/T height of 2.806 m.

The bracketed root resolves a small positive vapor fraction instead of clipping it to zero. The derivation uses SI units.

Phase mole fractions
ComponentFeed zLiquid xVapor y
10.333330.333330.66667
20.666670.666670.33333
3000
4000
Calculation details
Phase stateTwo phase
Mixed feed molecular weight53.45 kg/kmol
Feed molar flow101 kmol/h
Feed mass flow5,400 kg/h
Vapor mass flow9.855e-4 kg/h
Liquid mass flow5,400 kg/h
Actual vapor flow1.590e-4 Am³/h
Liquid flow7.714 m³/h
Gas velocity limit1.111 m/s
Liquid surge volume0.6429 m³
Required drum ID0.9354 m
Liquid surge depth0.9354 m
Gas velocity approach5.784e-6 %
Surge-depth approach100 %

Calculation inputs

Live updates

Feed mixture

Feed entries are normalized. Use z = 0 for an unused component.

kg/kmol
kg/kmol
kg/kmol
kg/kmol
Throughput
kg/h
kg/m³
kg/m³
Vessel screening
m/s
%
min
m
0 uses the calculated size
Back to results

Equations and assumptions

Phase endpoints
Σ zᵢKᵢ ≤ 1 → liquid · Σ zᵢ/Kᵢ ≤ 1 → vapor
Two-phase split
Σ zᵢ(Kᵢ − 1) / [1 + β(Kᵢ − 1)] = 0
Composition
xᵢ = zᵢ/[1 + β(Kᵢ − 1)] · yᵢ = Kᵢxᵢ
Drum height
HT/T = 2D + Vsurge / (πD²/4)

K-values are supplied at the flash temperature and pressure. The material balance uses the component molecular weights to convert mole split to phase mass flow. Compositions are reported only for phases that exist at the entered conditions.

The minimum shell ID is the larger of the gas area at the chosen design fraction of Souders–Brown velocity and the ID that stores liquid surge within a depth of one diameter. The sketch reserves two diameters above surge depth for gas disengagement and demister space.

Method references