Worked example
Hub temperature change for target 187.5 °F
- Required hub growth is 0.0015 + 0.0010 = 0.0025 in when the shaft stays at reference temperature.
- Divide this by the 2.000 in reference diameter times the steel expansion coefficient. Compare the calculated rise with the entered 200°F change.
Before using this result. Verify actual bore and shaft tolerances, hub material, heat treatment and assembly process. The computed rise is relative to the reference, so determine the absolute temperature separately.
Formulas and assumptions
- ΔL = αL₀ΔT
- Use a fractional expansion coefficient per degree and a temperature difference. Coefficients expressed in µm/m/°C are multiplied by 10⁻⁶.
- Clearance = Dᵦ(1 + αᵦΔTᵦ) − Dₛ(1 + αₛΔTₛ)
- Dᵦ is the hub bore at the reference temperature and Dₛ is that bore plus the initial interference. Negative clearance means interference remains.
- Required ΔTᵦ = (target clearance + interference + ΔDₛ) / (αᵦDᵦ)
- Keep the shaft temperature fixed at the entered change for this calculation. The result is a temperature change from reference.
Engineering references
Frequently asked questions
Should I add room temperature to the required steel hub temperature change?
Yes, add the change to the reference temperature on the same scale to find an estimated absolute hub temperature.
Why do I add the desired 0.001 in clearance to the interference?
The bore first has to grow past the shaft’s starting oversize. Additional growth creates the desired installation clearance.