Worked example

Length change -2.595 mm

  1. Enter 3.000 m and −50°C. Convert the 17.3 µm/m/°C coefficient to 17.3 × 10⁻⁶ per °C.
  2. Use 3,000 mm as the starting length in ΔL = αLΔT. A negative change indicates contraction from the original length.

Before using this result. Check actual grade, supports and reference dimensions. If the rail cannot move freely, evaluate thermal stresses at the restraints.

Formulas and assumptions

ΔL = αL₀ΔT
Use a fractional expansion coefficient per degree and a temperature difference. Coefficients expressed in µm/m/°C are multiplied by 10⁻⁶.
Clearance = Dᵦ(1 + αᵦΔTᵦ) − Dₛ(1 + αₛΔTₛ)
Dᵦ is the hub bore at the reference temperature and Dₛ is that bore plus the initial interference. Negative clearance means interference remains.
Required ΔTᵦ = (target clearance + interference + ΔDₛ) / (αᵦDᵦ)
Keep the shaft temperature fixed at the entered change for this calculation. The result is a temperature change from reference.

Engineering references

Frequently asked questions

Why does this stainless result have a minus sign?

The temperature difference is negative. With a positive expansion coefficient, cooling reduces length.

Can I use the same contraction for ferritic stainless?

Use that grade’s coefficient. Ferritic grades can have a materially different expansion response from austenitic grades.