Worked example
Installation clearance 0.02057 mm
- Expand the 40.000 mm hub using its aluminum coefficient. Contract the 40.040 mm shaft with its steel coefficient and the −18°C change.
- Subtract the contracted shaft from the expanded bore to find clearance. Compare it with the 0.020 mm target and the required hub rise at the entered shaft temperature.
Before using this result. Account for warming of the shaft and cooling of the hub during handling. Confirm surface damage, alignment and the assembly window before the production fit.
Formulas and assumptions
- ΔL = αL₀ΔT
- Use a fractional expansion coefficient per degree and a temperature difference. Coefficients expressed in µm/m/°C are multiplied by 10⁻⁶.
- Clearance = Dᵦ(1 + αᵦΔTᵦ) − Dₛ(1 + αₛΔTₛ)
- Dᵦ is the hub bore at the reference temperature and Dₛ is that bore plus the initial interference. Negative clearance means interference remains.
- Required ΔTᵦ = (target clearance + interference + ΔDₛ) / (αᵦDᵦ)
- Keep the shaft temperature fixed at the entered change for this calculation. The result is a temperature change from reference.
Engineering references
Frequently asked questions
Does cooling the 40.040 mm steel shaft reduce the required hub heating?
Yes. A smaller shaft needs less bore growth for the same installation clearance.
Why does the shaft expansion use 40.040 mm instead of 40 mm?
The shaft starts 0.040 mm larger than the nominal reference bore in this example. Thermal size change scales with its own initial diameter.