Worked example
Length change 0.3147 in
- Convert 20 ft to 240 in. The 6061 reference coefficient of 23.6 µm/m/°C is about 13.111 µin/in/°F.
- Multiply 240 in by 100°F and 13.111 × 10⁻⁶ per °F. The result is free growth for the full beam length.
Before using this result. Verify the alloy, actual end restraints and movement allowance across the service range. Supported or fixed members can develop forces as temperature changes.
Formulas and assumptions
- ΔL = αL₀ΔT
- Use a fractional expansion coefficient per degree and a temperature difference. Coefficients expressed in µm/m/°C are multiplied by 10⁻⁶.
- Clearance = Dᵦ(1 + αᵦΔTᵦ) − Dₛ(1 + αₛΔTₛ)
- Dᵦ is the hub bore at the reference temperature and Dₛ is that bore plus the initial interference. Negative clearance means interference remains.
- Required ΔTᵦ = (target clearance + interference + ΔDₛ) / (αᵦDᵦ)
- Keep the shaft temperature fixed at the entered change for this calculation. The result is a temperature change from reference.
Engineering references
Frequently asked questions
How much movement is needed at each end if the beam is fixed at its middle?
For uniform temperature and symmetric free ends, each end moves about half the full calculated length change. Verify the support conditions.
Can direct sunlight make the expansion larger than the air-temperature estimate?
Yes. Use the metal temperature swing. Sun exposure can heat the stock unevenly or above ambient air temperature.