Formulas and assumptions

ΔL = αL₀ΔT
Use a fractional expansion coefficient per degree and a temperature difference. Coefficients expressed in µm/m/°C are multiplied by 10⁻⁶.
Clearance = Dᵦ(1 + αᵦΔTᵦ) − Dₛ(1 + αₛΔTₛ)
Dᵦ is the hub bore at the reference temperature and Dₛ is that bore plus the initial interference. Negative clearance means interference remains.
Required ΔTᵦ = (target clearance + interference + ΔDₛ) / (αᵦDᵦ)
Keep the shaft temperature fixed at the entered change for this calculation. The result is a temperature change from reference.

Engineering references

Frequently asked questions

Do I add 32 when converting the thermal input to Celsius?

For a temperature difference, multiply degrees Fahrenheit by 5/9. The 32° offset applies when converting an absolute temperature reading.

Does a hole shrink when I heat the material around it?

A uniformly heated, unconstrained part expands its inner and outer dimensions. With a positive coefficient, the bore gets larger.