GasCompressLab

JT · Makogon · MDMT

Lean gas metering letdown

Lean gas enters a modest pressure letdown at 34 °C, allowing a comparison with a water-bearing lean-gas equilibrium estimate.

What to check

Check the margin after changing the entered JT coefficient to a gas-analysis value.

Operating readout

Edit inputs ↓
Outlet temp
20.8°C
JT temp change
-13.2K
Hydrate margin
16.45K
Heater duty
0kW
Temperature margins metOutlet temperature meets the entered MDMT and hydrate screening margins.
Choke valve and pressure–temperature pathJT LETDOWN / CHOKEkPa(a)P₁ 4800P₂ 1800ΔT -13.2 KP / T PATHGasHydrateMDMT · °C34-294800 kPa(a)1800 kPa(a)PREHEAT REQUIRED0 K
The gas and equilibrium curves share a pressure axis. The dashed MDMT line is based on the entered material limit.
Calculated details
Hydrate equilibrium estimate
4.35°C
Gas temperature above MDMT
49.8K
Required upstream temperature lift
0K
Estimated preheated inlet
34°C

Operating inputs

Letdown duty
kPa(a)
kPa(a)
°C
kg/h
°C
K
Gas properties
Properties are illustrative. Use a representative site value.
K/bar
Edit this value to override the preset. Negative values warm upon expansion.
kJ/(kg·K)

Calculation basis

Isenthalpic screening

Use ΔT = −μJT(P₁ − P₂) with a constant user-entered coefficient. A negative coefficient produces warming.

Hydrate and heater screen

Estimate wet natural-gas hydrate temperature from Makogon’s pressure relation with Elgibaly–Elkamel gas-gravity coefficients. Sensible preheater duty is ṁCₚ times the positive deficit to the higher of the hydrate and MDMT screens, including the entered buffer.