GasCompressLab

JT · Makogon · MDMT

Wet associated gas choke

A water-bearing associated gas case drops from 9,200 to 3,100 kPa(a) through a production choke.

What to check

The higher specific gravity shifts the hydrate estimate. Raising the inlet temperature shifts the process path without moving the equilibrium curve.

Operating readout

Edit inputs ↓
Outlet temp
-11.55°C
JT temp change
-33.55K
Hydrate margin
-25.44K
Heater duty
291.42kW
Hydrate screen failedOutlet gas is below the estimated hydrate temperature for wet natural gas.
Choke valve and pressure–temperature pathJT LETDOWN / CHOKEkPa(a)P₁ 9200P₂ 3100ΔT -33.6 KP / T PATHGasHydrateMDMT · °C22-359200 kPa(a)3100 kPa(a)PREHEAT REQUIRED28.4 K
The gas and equilibrium curves share a pressure axis. The dashed MDMT line is based on the entered material limit.
Calculated details
Hydrate equilibrium estimate
13.89°C
Gas temperature above MDMT
23.45K
Required upstream temperature lift
28.44K
Estimated preheated inlet
50.44°C

Operating inputs

Letdown duty
kPa(a)
kPa(a)
°C
kg/h
°C
K
Gas properties
Properties are illustrative. Use a representative site value.
K/bar
Edit this value to override the preset. Negative values warm upon expansion.
kJ/(kg·K)

Calculation basis

Isenthalpic screening

Use ΔT = −μJT(P₁ − P₂) with a constant user-entered coefficient. A negative coefficient produces warming.

Hydrate and heater screen

Estimate wet natural-gas hydrate temperature from Makogon’s pressure relation with Elgibaly–Elkamel gas-gravity coefficients. Sensible preheater duty is ṁCₚ times the positive deficit to the higher of the hydrate and MDMT screens, including the entered buffer.

Related worked examples