JT · Makogon · MDMT
Wet associated gas choke
A water-bearing associated gas case drops from 9,200 to 3,100 kPa(a) through a production choke.
The higher specific gravity shifts the hydrate estimate. Raising the inlet temperature shifts the process path without moving the equilibrium curve.
Operating readout
Edit inputs ↓- Outlet temp
- -11.55°C
- JT temp change
- -33.55K
- Hydrate margin
- -25.44K
- Heater duty
- 291.42kW
Calculated details
- Hydrate equilibrium estimate
- 13.89°C
- Gas temperature above MDMT
- 23.45K
- Required upstream temperature lift
- 28.44K
- Estimated preheated inlet
- 50.44°C
Operating inputs
Operating inputs
- Upstream pressure P₁
- 9,200kPa(a)
- Downstream pressure P₂
- 3,100kPa(a)
- Upstream temperature
- 22°C
- Gas mass flow
- 17,000kg/h
- Minimum metal temperature
- -35°C
- Temperature buffer
- 3K
- Gas preset
- Wet Associated Gas
- Gas gravity (air = 1)
- 0.8
- JT coefficient μJT
- 0.55K/bar
- Gas heat capacity Cp
- 2.17kJ/(kg·K)
Calculated details
- Hydrate equilibrium estimate
- 13.89°C
- Gas temperature above MDMT
- 23.45K
- Required upstream temperature lift
- 28.44K
- Estimated preheated inlet
- 50.44°C
Use the hydrate correlation for sweet, water-bearing natural gas in the working screen of G = 0.55–1.00 and 0.5–14 MPa. Treat extrapolation with care. CO₂, nitrogen, and hydrogen need composition-specific hydrate checks. Use a real-gas isenthalpic flash and a metal temperature analysis to assess phase change, water activity, inhibition, and material limits.
Calculation basis
Isenthalpic screening
Use ΔT = −μJT(P₁ − P₂) with a constant user-entered coefficient. A negative coefficient produces warming.
Hydrate and heater screen
Estimate wet natural-gas hydrate temperature from Makogon’s pressure relation with Elgibaly–Elkamel gas-gravity coefficients. Sensible preheater duty is ṁCₚ times the positive deficit to the higher of the hydrate and MDMT screens, including the entered buffer.
Related worked examples
-
Winter city-gate letdown →
Natural gas enters a cold-weather regulator at 16 °C and falls from 7,100 to 1,700 kPa(a).
-
Lean gas metering letdown →
Lean gas enters a modest pressure letdown at 34 °C, allowing a comparison with a water-bearing lean-gas equilibrium estimate.
-
Carbon dioxide pressure letdown →
A CO₂ pressure reduction illustrates a high linear JT coefficient and a low-metal-temperature check.
-
Nitrogen purge regulator →
A nitrogen-only stream passes a purge regulator with a user-entered JT coefficient of 0.28 K/bar.
-
Hydrogen inverse Joule–Thomson warming →
An ambient-temperature hydrogen screen reduces 11,000 kPa(a) to 3,000 kPa(a) with a negative JT coefficient.