GasCompressLab

API 521 · Restriction orifice

Cold gas inventory blowdown

A cold methane-rich vessel starts at 6 °C before adiabatic depressuring to 6.9 barg.

What to check

Review gas temperature against the material screen before interpreting a fast time as satisfactory.

Operating readout

Edit inputs ↓
Time to target
3.96min
Peak flow
15,413.15kg/h
Min. gas temp
-86.38°C
15-min RO ID
15.926mm
Cold blowdown below MDMTThe calculated minimum gas temperature is below the entered metal temperature screen.
Vessel blowdown pressure and mass-flow decayVESSEL / RESTRICTION / HEADERmmGas inventoryRO 31DEPRESSURINGP · kPa(a)Flow · kg/h41507911540000 min15.6 min15-MINUTE SCREEN3.96 min
Pressure and mass flow use independent scales. The vertical gate marks 15 minutes, and the plotted curves end at the selected pressure target.
Calculated details
Selected absolute target
790.8kPa(a)
Initial vapor inventory
731.15kg
Choked/subsonic transition pressure
261.93kPa(a)
Transition time if crossed
—
Starting regime
Choked
Target regime
Choked
Minimum gas temperature above MDMT
-57.38K

Operating inputs

Vessel and target
m³
bar(a)
°C
kPa(a)
°C
Restriction and gas
mm
kg/kmol

Calculation basis

Inventory and discharge

Use a uniform vapor inventory with fixed Z and k. Pressure follows mass to the power k for adiabatic operation, or mass directly for isothermal operation. Compute instantaneous gas flux with the choked expression below the critical backpressure ratio and the subsonic nozzle expression above it.

Integrate time

Integrate dM/ṁ down to the selected pressure with a transformed pressure coordinate. Solve the 15-minute orifice diameter using the inverse-area time scaling for this model.

Related worked examples