Worked example

Driven circular pile in clay

A driven circular pile extends through a uniform undrained clay profile.

Allowable
269.6 kN
Ultimate
741.5 kN
Shaft
669.1 kN
Tip
72.4 kN
Shaft friction & tip resistance Schematic
Shaft friction & tip resistance, schematic ShaftTipClay · α methodStatic load transferL 16 mShaft 90.2%Service / allowable81.6%
  • Shaft friction
  • Tip bearing
  • Embedment

Service compression is within the static allowable load.

Calculation details
Allowable minus service load49.6 kN
Tip area0.126 m²
Shaft perimeter1.257 m
Mean unit shaft resistance33.3 kPa
Unit tip resistance576 kPa
Effective vertical stress at tip—
Shaft share of static capacity90.2 %
Driving estimate basisOff
End-of-drive screening load—

Inputs

Pile or shaft geometry
Shaft and tip resistance
End-of-drive screening

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Shaft resistance depends on perimeter times embedment. Tip resistance depends on the plan area and 9su.

  1. A mean shaft stress of 33.28 kPa gives Qs = 669.134 kN. Tip stress times 0.126 m² gives Qp = 72.382 kN.
  2. Add Qs and Qp to get 741.516 kN. Divide by 2.75 for a static allowable load of 269.642 kN.
Allowable269.6 kNUltimate741.5 kNShaft669.1 kNTip72.4 kN
Original case inputs
InstallationDriven pile
Section shapeRound
Diameter or width0.4 m
Embedment L16 m
Static safety factor2.75
Service axial load220 kN
Soil modelClay (α)
Undrained strength su64 kPa
Adhesion factor α0.52
Driving methodNone

Method & assumptions

  1. Clay uses unit shaft adhesion αsu and tip resistance 9su. Sand uses unit friction βσ′v and tip resistance Nq*σ′v. Shaft friction is integrated along the embedment and multiplied by section perimeter.
  2. The homogeneous sand model uses the effective unit weight to compute σ′v. A nonzero critical depth caps stress in both the shaft integral and tip term. The static allowable load is (Qs + Qp) / F.S.
  3. ENR divides input energy by the sum of set and empirical displacement, then by 6. The displacement is 0.1 in for a single-acting hammer and 1 in for a drop hammer.
  4. FHWA Modified Gates uses 1.75√E log₁₀(10N) − 100 kips with developed hammer energy E in ft·lbf and N in blows per inch. The coefficient includes the stated 80% efficiency convention. A nonpositive estimate is unavailable.
  5. The driving formulas apply to driven piles at end of drive. Select site-calibrated parameters for the installation method and verify load transfer, settlement and capacity with appropriate field testing.

More worked examples