Worked example

Sand pile with capped effective stress

A critical-depth assumption limits the stress used below 14 m in a homogeneous sand screening model.

Allowable
781.5 kN
Ultimate
1,953.7 kN
Shaft
1,112.6 kN
Tip
841.2 kN
Shaft friction & tip resistance Schematic
Shaft friction & tip resistance, schematic ShaftTipSand · β methodStatic load transferL 23 mShaft 56.9%Service / allowable28.2%
  • Shaft friction
  • Tip bearing
  • Embedment

Service compression is within the static allowable load.

Calculation details
Allowable minus service load561.5 kN
Tip area0.196 m²
Shaft perimeter1.571 m
Mean unit shaft resistance30.8 kPa
Unit tip resistance4,284 kPa
Effective vertical stress at tip142.8 kPa
Shaft share of static capacity56.9 %
Driving estimate basisOff
End-of-drive screening load—

Inputs

Pile or shaft geometry
Shaft and tip resistance
Zero leaves the effective stress uncapped.
End-of-drive screening

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Integrate the rising friction above the cap and constant friction below it. Tip stress also uses the cap.

  1. A mean shaft stress of 30.795 kPa gives Qs = 1,112.576 kN. Tip stress times 0.196 m² gives Qp = 841.161 kN.
  2. Add Qs and Qp to get 1,953.738 kN. Divide by 2.5 for a static allowable load of 781.495 kN.
Allowable781.5 kNUltimate1,953.7 kNShaft1,112.6 kNTip841.2 kN
Original case inputs
InstallationDriven pile
Section shapeRound
Diameter or width0.5 m
Embedment L23 m
Static safety factor2.5
Service axial load220 kN
Soil modelSand (β)
Shaft factor β0.31
Effective weight γ′10.2 kN/m³
Tip factor Nq*30
Critical depth14 m
Driving methodNone

Method & assumptions

  1. Clay uses unit shaft adhesion αsu and tip resistance 9su. Sand uses unit friction βσ′v and tip resistance Nq*σ′v. Shaft friction is integrated along the embedment and multiplied by section perimeter.
  2. The homogeneous sand model uses the effective unit weight to compute σ′v. A nonzero critical depth caps stress in both the shaft integral and tip term. The static allowable load is (Qs + Qp) / F.S.
  3. ENR divides input energy by the sum of set and empirical displacement, then by 6. The displacement is 0.1 in for a single-acting hammer and 1 in for a drop hammer.
  4. FHWA Modified Gates uses 1.75√E log₁₀(10N) − 100 kips with developed hammer energy E in ft·lbf and N in blows per inch. The coefficient includes the stated 80% efficiency convention. A nonpositive estimate is unavailable.
  5. The driving formulas apply to driven piles at end of drive. Select site-calibrated parameters for the installation method and verify load transfer, settlement and capacity with appropriate field testing.