Worked example

Circular footing with water at its base

A circular equipment pad has a centered vertical load and groundwater at founding level.

Allowable
359.8 kPa
Ultimate
1,079.4 kPa
Overburden
21.6 kPa
Eff. width
2.1 m
Footing section & failure wedge Schematic
Footing section & failure wedge, schematic GradeB′ 2.1 mWater at 1.2 mBase at 1.2 mApplied / allowable51.4%
  • Bearing wedge
  • Groundwater
  • Footing base

Applied pressure is within the gross bearing screen.

Calculation details
Allowable minus applied174.8 kPa
Wedge effective unit weight γeff10.19 kN/m³
Cohesion factor Nc34.242
Overburden factor Nq19.981
Unit-weight factor Nγ17.7
Cohesion contribution534.2 kPa
Overburden contribution431.6 kPa
Soil wedge contribution113.7 kPa
Width after eccentricity B′2.1 m
Length after eccentricity L′2.1 m
Cohesion / surcharge inclination factor1
Wedge inclination factor1
Effective plan area3.46 m²
Gross allowable load1,246.2 kN

Inputs

Footing geometry
Soil and groundwater
Depth from grade. Use a deep value for dry conditions.
Vertical service load divided by effective area.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Moist weight governs the overburden. The bearing wedge is submerged, and the circular shape factor applies to its contribution.

  1. The governing effective dimension is 2.1 m. Overburden q′ is 21.6 kPa and the wedge unit weight is 10.193 kN/m³.
  2. Add cohesion, overburden and wedge contributions of 534.183 kPa, 431.588 kPa and 113.666 kPa to get qᵤ = 1,079.437 kPa.
  3. Divide qᵤ by 3 to get a gross allowable pressure of 359.812 kPa.
Allowable359.8 kPaUltimate1,079.4 kPaOverburden21.6 kPaEff. width2.1 m
Original case inputs
Bearing methodTerzaghi
Footing shapeCircle
Width or diameter B2.1 m
Base depth Df1.2 m
Cohesion c′12 kPa
Friction angle φ′29 °
Moist weight γ18 kN/m³
Saturated weight γsat20 kN/m³
Water table depth Dw1.2 m
Bearing safety factor3
Applied gross pressure185 kPa

Method & assumptions

  1. qᵤ = c′·Nc·sc·dc·ic + q′·Nq·sq·dq·iq + ½ γeff·B′·Nγ·sγ·dγ·iγ. The conservative gross allowable screen is qᵤ / F.S. Compare against vertical service load per effective area.
  2. Effective overburden q′ sums moist soil above the water table and buoyant soil below it. The wedge term averages moist and buoyant unit weights over the smaller effective dimension below the base.
  3. Terzaghi uses his general shear Nq and Nc factors and linearly interpolates tabulated Nγ. Strip, square and circular shape factors follow the general shear model. For a rectangle, use the ratio of the smaller to the larger effective dimension.
  4. Meyerhof uses Nq = exp(π tan φ′) tan²(45° + φ′/2), Nc = (Nq − 1) cot φ′ and Nγ = (Nq − 1) tan(1.4φ′). Depth factors use the original width in Df/B. The circular screen uses a unit plan aspect ratio for vertical load.
  5. Plan eccentricity reduces B′ = B − 2eₓ and L′ = L − 2eᵧ. Inclined Meyerhof loading uses a centered load, unit shape factors and angle θ from vertical. The wedge factor reaches zero at θ ≥ φ′ for frictional soil. Check sliding, settlement and contact separately.