Worked example

Undrained strip footing in clay

An idealized short-term total-stress check treats 42 kPa as undrained cohesion with φ = 0.

Allowable
84 kPa
Ultimate
252 kPa
Overburden
12.6 kPa
Eff. width
1.8 m
Footing section & failure wedge Schematic
Footing section & failure wedge, schematic GradeB′ 1.8 mWater below wedgeBase at 0.7 mApplied / allowable85.7%
  • Bearing wedge
  • Groundwater
  • Footing base

Applied pressure is within the gross bearing screen.

Calculation details
Allowable minus applied12 kPa
Wedge effective unit weight γeff18 kN/m³
Cohesion factor Nc5.7
Overburden factor Nq1
Unit-weight factor Nγ0
Cohesion contribution239.4 kPa
Overburden contribution12.6 kPa
Soil wedge contribution0 kPa
Width after eccentricity B′1.8 m
Length after eccentricity L′—
Cohesion / surcharge inclination factor1
Wedge inclination factor1
Effective plan area—
Gross allowable load—

Inputs

Footing geometry
Soil and groundwater
Depth from grade. Use a deep value for dry conditions.
Vertical service load divided by effective area.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Terzaghi uses Nc = 5.7 and Nγ = 0. With water below the wedge, the unit weight for the total-stress surcharge is 18 kN/m³.

  1. The governing effective dimension is 1.8 m. Overburden q′ is 12.6 kPa and the wedge unit weight is 18 kN/m³.
  2. Add cohesion, overburden and wedge contributions of 239.4 kPa, 12.6 kPa and 0 kPa to get qᵤ = 252 kPa.
  3. Divide qᵤ by 3 to get a gross allowable pressure of 84 kPa.
Allowable84 kPaUltimate252 kPaOverburden12.6 kPaEff. width1.8 m
Original case inputs
Bearing methodTerzaghi
Footing shapeStrip
Width or diameter B1.8 m
Base depth Df0.7 m
Width eccentricity eₓ0 m
Cohesion c′42 kPa
Friction angle φ′0 °
Moist weight γ18 kN/m³
Saturated weight γsat18 kN/m³
Water table depth Dw12 m
Bearing safety factor3
Applied gross pressure72 kPa

Method & assumptions

  1. qᵤ = c′·Nc·sc·dc·ic + q′·Nq·sq·dq·iq + ½ γeff·B′·Nγ·sγ·dγ·iγ. The conservative gross allowable screen is qᵤ / F.S. Compare against vertical service load per effective area.
  2. Effective overburden q′ sums moist soil above the water table and buoyant soil below it. The wedge term averages moist and buoyant unit weights over the smaller effective dimension below the base.
  3. Terzaghi uses his general shear Nq and Nc factors and linearly interpolates tabulated Nγ. Strip, square and circular shape factors follow the general shear model. For a rectangle, use the ratio of the smaller to the larger effective dimension.
  4. Meyerhof uses Nq = exp(π tan φ′) tan²(45° + φ′/2), Nc = (Nq − 1) cot φ′ and Nγ = (Nq − 1) tan(1.4φ′). Depth factors use the original width in Df/B. The circular screen uses a unit plan aspect ratio for vertical load.
  5. Plan eccentricity reduces B′ = B − 2eₓ and L′ = L − 2eᵧ. Inclined Meyerhof loading uses a centered load, unit shape factors and angle θ from vertical. The wedge factor reaches zero at θ ≥ φ′ for frictional soil. Check sliding, settlement and contact separately.