Worked example
Undrained strip footing in clay
An idealized short-term total-stress check treats 42 kPa as undrained cohesion with φ = 0.
Results
Edit inputs ↓- Allowable
- 84 kPa
- Ultimate
- 252 kPa
- Overburden
- 12.6 kPa
- Eff. width
- 1.8 m
- Bearing wedge
- Groundwater
- Footing base
Applied pressure is within the gross bearing screen.
Calculation details
| Allowable minus applied | 12 kPa |
|---|---|
| Wedge effective unit weight γeff | 18 kN/m³ |
| Cohesion factor Nc | 5.7 |
| Overburden factor Nq | 1 |
| Unit-weight factor Nγ | 0 |
| Cohesion contribution | 239.4 kPa |
| Overburden contribution | 12.6 kPa |
| Soil wedge contribution | 0 kPa |
| Width after eccentricity B′ | 1.8 m |
| Length after eccentricity L′ | — |
| Cohesion / surcharge inclination factor | 1 |
| Wedge inclination factor | 1 |
| Effective plan area | — |
| Gross allowable load | — |
GeotechSoilLab · Screening sheet · Metric SI
Undrained strip footing in clay
| Bearing method | Terzaghi |
|---|---|
| Footing shape | Strip |
| Width or diameter B | 1.8 m |
| Base depth Df | 0.7 m |
| Width eccentricity eₓ | 0 m |
| Cohesion c′ | 42 kPa |
| Friction angle φ′ | 0 ° |
| Moist weight γ | 18 kN/m³ |
| Saturated weight γsat | 18 kN/m³ |
| Water table depth Dw | 12 m |
| Bearing safety factor | 3 |
| Applied gross pressure | 72 kPa |
| Allowable | 84 kPa |
|---|---|
| Ultimate | 252 kPa |
| Overburden | 12.6 kPa |
| Eff. width | 1.8 m |
| Allowable minus applied | 12 kPa |
| Wedge effective unit weight γeff | 18 kN/m³ |
| Cohesion factor Nc | 5.7 |
| Overburden factor Nq | 1 |
| Unit-weight factor Nγ | 0 |
| Cohesion contribution | 239.4 kPa |
| Overburden contribution | 12.6 kPa |
| Soil wedge contribution | 0 kPa |
| Width after eccentricity B′ | 1.8 m |
| Length after eccentricity L′ | — |
| Cohesion / surcharge inclination factor | 1 |
| Wedge inclination factor | 1 |
| Effective plan area | — |
| Gross allowable load | — |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
Terzaghi uses Nc = 5.7 and Nγ = 0. With water below the wedge, the unit weight for the total-stress surcharge is 18 kN/m³.
- The governing effective dimension is 1.8 m. Overburden q′ is 12.6 kPa and the wedge unit weight is 18 kN/m³.
- Add cohesion, overburden and wedge contributions of 239.4 kPa, 12.6 kPa and 0 kPa to get qᵤ = 252 kPa.
- Divide qᵤ by 3 to get a gross allowable pressure of 84 kPa.
Allowable84 kPaUltimate252 kPaOverburden12.6 kPaEff. width1.8 m
Original case inputs
| Bearing method | Terzaghi |
|---|---|
| Footing shape | Strip |
| Width or diameter B | 1.8 m |
| Base depth Df | 0.7 m |
| Width eccentricity eₓ | 0 m |
| Cohesion c′ | 42 kPa |
| Friction angle φ′ | 0 ° |
| Moist weight γ | 18 kN/m³ |
| Saturated weight γsat | 18 kN/m³ |
| Water table depth Dw | 12 m |
| Bearing safety factor | 3 |
| Applied gross pressure | 72 kPa |
Method & assumptions
- qᵤ = c′·Nc·sc·dc·ic + q′·Nq·sq·dq·iq + ½ γeff·B′·Nγ·sγ·dγ·iγ. The conservative gross allowable screen is qᵤ / F.S. Compare against vertical service load per effective area.
- Effective overburden q′ sums moist soil above the water table and buoyant soil below it. The wedge term averages moist and buoyant unit weights over the smaller effective dimension below the base.
- Terzaghi uses his general shear Nq and Nc factors and linearly interpolates tabulated Nγ. Strip, square and circular shape factors follow the general shear model. For a rectangle, use the ratio of the smaller to the larger effective dimension.
- Meyerhof uses Nq = exp(π tan φ′) tan²(45° + φ′/2), Nc = (Nq − 1) cot φ′ and Nγ = (Nq − 1) tan(1.4φ′). Depth factors use the original width in Df/B. The circular screen uses a unit plan aspect ratio for vertical load.
- Plan eccentricity reduces B′ = B − 2eₓ and L′ = L − 2eᵧ. Inclined Meyerhof loading uses a centered load, unit shape factors and angle θ from vertical. The wedge factor reaches zero at θ ≥ φ′ for frictional soil. Check sliding, settlement and contact separately.
More worked examples
- Dry strip footing in sandA continuous wall bears on medium-dense sand. The seasonal water table lies below the bearing wedge.
- Square footing with water at gradeA square column pad supports a service load in saturated sand during the high-water season.
- Circular footing with water at its baseA circular equipment pad has a centered vertical load and groundwater at founding level.
- Water table within a footing wedgeThe water table is 1.2 m below the base of a 2.4 m wide rectangular footing.
- Eccentric rectangular footing by MeyerhofA column moment shifts the vertical service load toward one edge of a rectangular pad.
- Embedded square footing by MeyerhofAn embedded square pad bears in a dense granular layer below loose surface fill.