Worked example

Dry strip footing in sand

A continuous wall bears on medium-dense sand. The seasonal water table lies below the bearing wedge.

Allowable
262.2 kPa
Ultimate
786.7 kPa
Overburden
13.5 kPa
Eff. width
1.6 m
Footing section & failure wedge Schematic
Footing section & failure wedge, schematic GradeB′ 1.6 mWater below wedgeBase at 0.75 mApplied / allowable43.9%
  • Bearing wedge
  • Groundwater
  • Footing base

Applied pressure is within the gross bearing screen.

Calculation details
Allowable minus applied147.2 kPa
Wedge effective unit weight γeff18 kN/m³
Cohesion factor Nc44.036
Overburden factor Nq28.517
Unit-weight factor Nγ27.9
Cohesion contribution0 kPa
Overburden contribution385 kPa
Soil wedge contribution401.8 kPa
Width after eccentricity B′1.6 m
Length after eccentricity L′—
Cohesion / surcharge inclination factor1
Wedge inclination factor1
Effective plan area—
Gross allowable load—

Inputs

Footing geometry
Soil and groundwater
Depth from grade. Use a deep value for dry conditions.
Vertical service load divided by effective area.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

The cohesion contribution drops out. Overburden and soil weight form the full gross ultimate pressure.

  1. The governing effective dimension is 1.6 m. Overburden q′ is 13.5 kPa and the wedge unit weight is 18 kN/m³.
  2. Add cohesion, overburden and wedge contributions of 0 kPa, 384.974 kPa and 401.76 kPa to get qᵤ = 786.734 kPa.
  3. Divide qᵤ by 3 to get a gross allowable pressure of 262.245 kPa.
Allowable262.2 kPaUltimate786.7 kPaOverburden13.5 kPaEff. width1.6 m
Original case inputs
Bearing methodTerzaghi
Footing shapeStrip
Width or diameter B1.6 m
Base depth Df0.75 m
Width eccentricity eₓ0 m
Cohesion c′0 kPa
Friction angle φ′32 °
Moist weight γ18 kN/m³
Saturated weight γsat20 kN/m³
Water table depth Dw8 m
Bearing safety factor3
Applied gross pressure115 kPa

Method & assumptions

  1. qᵤ = c′·Nc·sc·dc·ic + q′·Nq·sq·dq·iq + ½ γeff·B′·Nγ·sγ·dγ·iγ. The conservative gross allowable screen is qᵤ / F.S. Compare against vertical service load per effective area.
  2. Effective overburden q′ sums moist soil above the water table and buoyant soil below it. The wedge term averages moist and buoyant unit weights over the smaller effective dimension below the base.
  3. Terzaghi uses his general shear Nq and Nc factors and linearly interpolates tabulated Nγ. Strip, square and circular shape factors follow the general shear model. For a rectangle, use the ratio of the smaller to the larger effective dimension.
  4. Meyerhof uses Nq = exp(π tan φ′) tan²(45° + φ′/2), Nc = (Nq − 1) cot φ′ and Nγ = (Nq − 1) tan(1.4φ′). Depth factors use the original width in Df/B. The circular screen uses a unit plan aspect ratio for vertical load.
  5. Plan eccentricity reduces B′ = B − 2eₓ and L′ = L − 2eᵧ. Inclined Meyerhof loading uses a centered load, unit shape factors and angle θ from vertical. The wedge factor reaches zero at θ ≥ φ′ for frictional soil. Check sliding, settlement and contact separately.