Shallow footing bearing capacity

Screen Terzaghi or Meyerhof bearing capacity with footing shape, eccentricity and groundwater corrections.

Allowable
309.3 kPa
Ultimate
927.9 kPa
Overburden
16.2 kPa
Eff. width
2 m
Footing section & failure wedge Schematic
Footing section & failure wedge, schematic GradeB′ 2 mWater at 1.4 mBase at 0.9 mApplied / allowable45.3%
  • Bearing wedge
  • Groundwater
  • Footing base

Applied pressure is within the gross bearing screen.

Calculation details
Allowable minus applied169.3 kPa
Wedge effective unit weight γeff12.15 kN/m³
Cohesion factor Nc37.162
Overburden factor Nq22.456
Unit-weight factor Nγ19.7
Cohesion contribution356.8 kPa
Overburden contribution363.8 kPa
Soil wedge contribution207.4 kPa
Width after eccentricity B′2 m
Length after eccentricity L′3 m
Cohesion / surcharge inclination factor1
Wedge inclination factor1
Effective plan area6 m²
Gross allowable load1,855.8 kN

Inputs

Footing geometry
Soil and groundwater
Depth from grade. Use a deep value for dry conditions.
Vertical service load divided by effective area.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Method & assumptions

  1. qᵤ = c′·Nc·sc·dc·ic + q′·Nq·sq·dq·iq + ½ γeff·B′·Nγ·sγ·dγ·iγ. The conservative gross allowable screen is qᵤ / F.S. Compare against vertical service load per effective area.
  2. Effective overburden q′ sums moist soil above the water table and buoyant soil below it. The wedge term averages moist and buoyant unit weights over the smaller effective dimension below the base.
  3. Terzaghi uses his general shear Nq and Nc factors and linearly interpolates tabulated Nγ. Strip, square and circular shape factors follow the general shear model. For a rectangle, use the ratio of the smaller to the larger effective dimension.
  4. Meyerhof uses Nq = exp(π tan φ′) tan²(45° + φ′/2), Nc = (Nq − 1) cot φ′ and Nγ = (Nq − 1) tan(1.4φ′). Depth factors use the original width in Df/B. The circular screen uses a unit plan aspect ratio for vertical load.
  5. Plan eccentricity reduces B′ = B − 2eₓ and L′ = L − 2eᵧ. Inclined Meyerhof loading uses a centered load, unit shape factors and angle θ from vertical. The wedge factor reaches zero at θ ≥ φ′ for frictional soil. Check sliding, settlement and contact separately.