Worked example

Water table within a footing wedge

The water table is 1.2 m below the base of a 2.4 m wide rectangular footing.

Allowable
277.5 kPa
Ultimate
832.4 kPa
Overburden
16.2 kPa
Eff. width
2.4 m
Footing section & failure wedge Schematic
Footing section & failure wedge, schematic GradeB′ 2.4 mWater at 2.1 mBase at 0.9 mApplied / allowable52.3%
  • Bearing wedge
  • Groundwater
  • Footing base

Applied pressure is within the gross bearing screen.

Calculation details
Allowable minus applied132.5 kPa
Wedge effective unit weight γeff14.1 kN/m³
Cohesion factor Nc37.162
Overburden factor Nq22.456
Unit-weight factor Nγ19.7
Cohesion contribution175.4 kPa
Overburden contribution363.8 kPa
Soil wedge contribution293.3 kPa
Width after eccentricity B′2.4 m
Length after eccentricity L′4 m
Cohesion / surcharge inclination factor1
Wedge inclination factor1
Effective plan area9.6 m²
Gross allowable load2,663.8 kN

Inputs

Footing geometry
Soil and groundwater
Depth from grade. Use a deep value for dry conditions.
Vertical service load divided by effective area.

Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.

Worked result

Half the effective wedge interval is moist and half is submerged, so the wedge weight lies between the two values.

  1. The governing effective dimension is 2.4 m. Overburden q′ is 16.2 kPa and the wedge unit weight is 14.097 kN/m³.
  2. Add cohesion, overburden and wedge contributions of 175.407 kPa, 363.783 kPa and 293.256 kPa to get qᵤ = 832.446 kPa.
  3. Divide qᵤ by 3 to get a gross allowable pressure of 277.482 kPa.
Allowable277.5 kPaUltimate832.4 kPaOverburden16.2 kPaEff. width2.4 m
Original case inputs
Bearing methodTerzaghi
Footing shapeRectangle
Width or diameter B2.4 m
Length L4 m
Base depth Df0.9 m
Width eccentricity eₓ0 m
Length eccentricity eᵧ0 m
Cohesion c′4 kPa
Friction angle φ′30 °
Moist weight γ18 kN/m³
Saturated weight γsat20 kN/m³
Water table depth Dw2.1 m
Bearing safety factor3
Applied gross pressure145 kPa

Method & assumptions

  1. qᵤ = c′·Nc·sc·dc·ic + q′·Nq·sq·dq·iq + ½ γeff·B′·Nγ·sγ·dγ·iγ. The conservative gross allowable screen is qᵤ / F.S. Compare against vertical service load per effective area.
  2. Effective overburden q′ sums moist soil above the water table and buoyant soil below it. The wedge term averages moist and buoyant unit weights over the smaller effective dimension below the base.
  3. Terzaghi uses his general shear Nq and Nc factors and linearly interpolates tabulated Nγ. Strip, square and circular shape factors follow the general shear model. For a rectangle, use the ratio of the smaller to the larger effective dimension.
  4. Meyerhof uses Nq = exp(π tan φ′) tan²(45° + φ′/2), Nc = (Nq − 1) cot φ′ and Nγ = (Nq − 1) tan(1.4φ′). Depth factors use the original width in Df/B. The circular screen uses a unit plan aspect ratio for vertical load.
  5. Plan eccentricity reduces B′ = B − 2eₓ and L′ = L − 2eᵧ. Inclined Meyerhof loading uses a centered load, unit shape factors and angle θ from vertical. The wedge factor reaches zero at θ ≥ φ′ for frictional soil. Check sliding, settlement and contact separately.

More worked examples