Worked example
Relative density of a loose sand
A field sand specimen is compared with minimum and maximum index void ratios.
Results
Edit inputs ↓- Dry weight
- 96.12 pcf
- Void ratio
- 0.721
- Saturation
- 29.4 %
- Porosity
- 41.9 %
- Solids
- Water
- Lab point
Measured dry weight is within the zero-air-voids ceiling at this water content.
Calculation details
| Bulk unit weight γ | 103.81 pcf |
|---|---|
| Saturated unit weight γsat | 122.28 pcf |
| Buoyant unit weight γ′ | 59.85 pcf |
| Air fraction of total volume | 29.6 % |
| Zero-air-voids dry weight | 136.5 pcf |
| Ceiling minus measured dry weight | 40.37 pcf |
| Relative density Dr | 36 % |
GeotechSoilLab · Screening sheet · US customary
Relative density of a loose sand
| Water content w | 8 % |
|---|---|
| Solids specific gravity Gs | 2.65 |
| Measured weight basis | Dry weight |
| Measured unit weight | 96.12479 pcf |
| Relative density Dr | Check Dr |
| Minimum void ratio | 0.42 |
| Maximum void ratio | 0.89 |
| Dry weight | 96.12 pcf |
|---|---|
| Void ratio | 0.721 |
| Saturation | 29.4 % |
| Porosity | 41.9 % |
| Bulk unit weight γ | 103.81 pcf |
| Saturated unit weight γsat | 122.28 pcf |
| Buoyant unit weight γ′ | 59.85 pcf |
| Air fraction of total volume | 29.6 % |
| Zero-air-voids dry weight | 136.5 pcf |
| Ceiling minus measured dry weight | 40.37 pcf |
| Relative density Dr | 36 % |
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Engineering screening estimates. Use site-specific boring logs, appropriate test data and review by a licensed geotechnical PE before design or construction.
Worked result
An in-place void ratio near the maximum maps to a low relative density.
- Use γd = 96.125 pcf and Gs = 2.65 to find e = 0.721 and porosity = 41.9%.
- At w = 8%, wGs/e gives a saturation of 29.4%.
- The zero-air-voids ceiling at this water content is 136.497 pcf. Ceiling minus measured dry weight is 40.372 pcf.
Dry weight96.12 pcfVoid ratio0.721Saturation29.4 %Porosity41.9 %
Original case inputs
| Water content w | 8 % |
|---|---|
| Solids specific gravity Gs | 2.65 |
| Measured weight basis | Dry weight |
| Measured unit weight | 96.12479 pcf |
| Relative density Dr | Check Dr |
| Minimum void ratio | 0.42 |
| Maximum void ratio | 0.89 |
Method & assumptions
- A bulk unit weight converts to γd = γ/(1 + w). The model takes w as a mass ratio and uses γw = 9.80665 kN/m³.
- e = Gsγw/γd − 1, n = e/(1 + e) and Sr = wGs/e. Saturated weight is γw(Gs + e)/(1 + e). Buoyant weight subtracts γw from that value.
- The zero-air-voids curve uses γd,zav = Gsγw/(1 + wGs). A specimen above the curve implies more water volume than void space. The plot preserves the measured point for diagnosis.
- For granular material, enter index-density void ratios to compute Dr = (emax − e)/(emax − emin). Relative density and percent Proctor compaction use different reference measurements.
More worked examples
- Dry unit weight from a bulk measurementA moist specimen’s total weight and volume give a bulk unit weight of 19.4 kN/m³.
- Phase volumes for oven-dry sandA granular specimen has been oven-dried and compacted into a known volume.
- Specimen on the zero-air-voids curveLab values are chosen to represent a fully saturated specimen with e = 0.54.
- Lab data above the zero-air-voids ceilingA reported Proctor point pairs unusually high dry weight with high water content.
- Silty clay bulk and buoyant weightsA moist silty-clay sample is weighed at its natural water content.