Cold-weather sealant movement

A tall aluminum frame experiences a broad service temperature range.

ASTM C1401 · 1:1 to 3:1

Inputs

Lite and wind suction
m
m
kPa
kPa

138 kPa is approximately 20 psi.

Movement and proposed joint
K
µm/(m·K)
%

Use the approved structural shear strain.

mm
mm

Screening result

The proposed bite or glue line is smaller than required.

Fail
Required bite
6.34mm
Min. glue line
21.07mm
Bite : glue
2.3 : 1
Movement
2.11mm
Structural silicone section and joint geometryStructural silicone joint. Required bite 6.34 mm. Min. glue line 21.07 mm. Bite : glue 2.3 : 1. Movement 2.11 mm.Structural glazing sectionLite width 1.25 m · 1.4 kPa suctionGlassSiliconeMullionProposed bond geometryThermal travel 2.11 mmBite 23 mmGlue line 10 mmBite-to-glue ratio (1:1–3:1)0:12:14:1+

Calculation details

Wind-only structural bite
6.341 mm
Movement-only glue line
21.07 mm
Compatible bite before rounding up
21.07 mm
Compatible glue line before rounding up
21.07 mm
Governing dimensional utilization
210.7 %

Formula trace in SI

  1. Wind suction bite

    Bwind = aₛ q / (2 σallow)

    1.25 m × 1.4 kPa / (2 × 138 kPa) → 6.341 mm.

  2. Differential movement

    Δ = |αAl − αglass| × Llong/2 × ΔT

    Glass CTE 9 µm/(m·K), relative travel 2.107 mm.

  3. Glue line and limits

    Gmove = Δ/γallow; B,G ≥ 6 mm; G ≤ B ≤ 3G

    At 10 % shear strain, Gmove = 21.07 mm. Minimum compatible B × G = 21.07 × 21.07 mm.