GlassFacadeLab · ASTM C1401 · 1:1 to 3:1
Cold-weather sealant movement
Worked example · SI
Fail · The proposed bite or glue line is smaller than required.
Inputs
- Lite width a
- 1.25 m
- Lite height b
- 3.5 m
- Wind suction magnitude
- 1.4 kPa
- Allowable sealant tension
- 138 kPa
- Temperature excursion
- 86 K
- Aluminum expansion coefficient
- 23 µm/(m·K)
- Allowable shear strain
- 10 %
- Proposed bite
- 23 mm
- Proposed glue line
- 10 mm
Results
- Required bite
- 6.34 mm
- Min. glue line
- 21.07 mm
- Bite : glue
- 2.3 : 1
- Movement
- 2.11 mm
- Wind-only structural bite
- 6.341 mm
- Movement-only glue line
- 21.07 mm
- Compatible bite before rounding up
- 21.07 mm
- Compatible glue line before rounding up
- 21.07 mm
- Governing dimensional utilization
- 210.7 %
Formula trace in SI
Wind suction bite
Bwind = aₛ q / (2 σallow)
1.25 m × 1.4 kPa / (2 × 138 kPa) → 6.341 mm.
Differential movement
Δ = |αAl − αglass| × Llong/2 × ΔT
Glass CTE 9 µm/(m·K), relative travel 2.107 mm.
Glue line and limits
Gmove = Δ/γallow; B,G ≥ 6 mm; G ≤ B ≤ 3G
At 10 % shear strain, Gmove = 21.07 mm. Minimum compatible B × G = 21.07 × 21.07 mm.