Downtown traffic asymmetric IGU

An asymmetric IGU is screened at a low-frequency road traffic band.

Mass–air–mass · STC/OITC screening

Inputs

Double glazing
mm
mm
mm
Noise target
Hz
dB

Screening result

Current thickness ratio separates the two dip centers.

Pass
Target-band TL
35.9dB
Cavity dip
138Hz
STC estimate
44
OITC estimate
32
Double-pane section and transmission-loss spectrumGlazing acoustics. Target-band TL 35.9 dB. Cavity dip 138 Hz. STC estimate 44. OITC estimate 32.Two-pane acoustic section6 mm and 10 mm panesGap 20 mmTransmission lossModeled dB · log frequency80050 Hz10 kHzCavity dipCoincidenceTargetPredicted target-band reserve−10 dBTarget+10 dB

Calculation details

Combined glass surface mass
40 kg/m²
Mass-law loss at target band
33 dB
Pane 1 coincidence frequency
1993 Hz
Pane 2 coincidence frequency
1196 Hz
Target-band reserve
6.9 dB
Thick-to-thin pane ratio
1.667
Pane asymmetry
Current thickness ratio separates the two dip centers.

Formula trace in SI

  1. Mass law

    TLmass = 20 log₁₀[(m₁ + m₂) f] − 47

    40 kg/m² at 250 Hz → 33 dB.

  2. Resonant frequencies

    fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)

    Cavity 138 Hz, glass 1993 Hz and 1196 Hz.

  3. Target band

    TLscreen = TLmass + cavity gain − resonance and coincidence penalties

    Predicted 35.9 dB, reserve 6.9 dB.

  4. Screening classes

    Speech contour fit and A-weighted outdoor spectrum energy loss

    STC estimate 44, OITC estimate 32 from the synthetic spectrum.