GlassFacadeLab · Mass–air–mass · STC/OITC screening
Downtown traffic asymmetric IGU
Worked example · SI
Pass · Current thickness ratio separates the two dip centers.
Inputs
- Pane 1 thickness
- 6 mm
- Pane 2 thickness
- 10 mm
- Air or gas cavity
- 20 mm
- Cavity gas
- Air
- Laminated damping
- Damped coincidence estimate
- Target band center
- 250 Hz
- Target transmission loss
- 29 dB
Results
- Target-band TL
- 35.9 dB
- Cavity dip
- 138 Hz
- STC estimate
- 44
- OITC estimate
- 32
- Combined glass surface mass
- 40 kg/m²
- Mass-law loss at target band
- 33 dB
- Pane 1 coincidence frequency
- 1993 Hz
- Pane 2 coincidence frequency
- 1196 Hz
- Target-band reserve
- 6.9 dB
- Thick-to-thin pane ratio
- 1.667
Formula trace in SI
Mass law
TLmass = 20 log₁₀[(m₁ + m₂) f] − 47
40 kg/m² at 250 Hz → 33 dB.
Resonant frequencies
fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)
Cavity 138 Hz, glass 1993 Hz and 1196 Hz.
Target band
TLscreen = TLmass + cavity gain − resonance and coincidence penalties
Predicted 35.9 dB, reserve 6.9 dB.
Screening classes
Speech contour fit and A-weighted outdoor spectrum energy loss
STC estimate 44, OITC estimate 32 from the synthetic spectrum.