Flat mall skylight under snow

A level skylight sees plan-area roof snow and downward normal wind.

GANA setting-block screen

Inputs

Slope, glass and loading
°
m
m
mm
kg/m³
kPa
kPa

Positive presses toward the frame.

Setting blocks
mm
Shore A
%

25% places blocks at the quarter points.

MPa

Use the block manufacturer’s allowable pressure.

Screening result

Both modeled setting blocks satisfy the selected length and bearing checks.

Pass
Normal load
2.45kPa
In-plane force
0N
Min. block
101.6mm
Block bearing
0MPa
Sloped-glass free-body diagram and setting blocksSkylight snow and blocks. Normal load 2.45 kPa. In-plane force 0 N. Min. block 101.6 mm. Block bearing 0 MPa.Sloped glass load components0 ° from horizontalWeightNormalThrustLower edge block placementBlock length 108 mm25 % from each cornerGoverning block demand0%100% limit200%+

Calculation details

Total glass weight
790.1 N
Total glass mass
80.568 kg
Dead load per glass area
0.35 kPa
Snow resultant per glass area
1.75 kPa
Glass-only downslope thrust
0 N
Gravity and snow thrust per block
0 N
Minimum block width (glass + 1/8 in)
17.455 mm
Clearance from corner to block end
256 mm

Formula trace in SI

  1. Weight and snow basis

    W = ρ t A g; p_snow = p_roof cos θ for plan-area pressure

    W = 790.1 N, converted p_snow = 1.75 kPa.

  2. Slope components

    qn = (pd + ps) cos θ + pw; F∥ = (pd + ps) A sin θ

    Angle 0 °, qn = 2.45 kPa, F∥ = 0 N.

  3. Block length

    ℓmin = max(4 in, 0.1 in × area in ft²)

    Per-block minimum 101.6 mm, provided 108 mm.

  4. Edge bearing

    pblock = F∥ / (2 ℓblock tglass)

    0 MPa versus 0.85 MPa allowance.