Partially shaded corner lite

A shaded frame perimeter surrounds a highly exposed tempered corner lite.

Solar absorption · Edge restraint

Inputs

Solar and edge conditions
W/m²
°C
°C
mm
W/(m²·K)
Glass edge
MPa

Enter a verified reference when available.

Screening result

Modeled edge tension is within the entered allowance.

Pass
Center–edge ΔT
48.9K
Edge stress
29.82MPa
Edge allowance
48MPa
Safety factor
1.61
Shaded glass perimeter and center-to-edge temperaturesSolar thermal edge stress. Center–edge ΔT 48.9 K. Edge stress 29.82 MPa. Edge allowance 48 MPa. Safety factor 1.61.Sunlit center and cool perimeterAbsorptance 0.57Shaded band 110 mmCross-pane temperatureEdge 17 °C · center 65.9 °CEdgeCenterEdgeΔT 48.9 KEdge tensile demand0%100% limit200%+

Calculation details

Sunlit center temperature
65.9 °C
Shaded edge temperature
17 °C
Absorbed solar flux
598.5 W/m²
Frame restraint assumption
0.968
Edge stress utilization
62.1 %

Formula trace in SI

  1. Absorbed heat

    qsolar = α I; Tcenter = Tindoor + qsolar/heff

    Absorbed 598.5 W/m², center 65.9 °C.

  2. Edge tension

    σth = E αglass max(ΔT, 0) Kframe

    ΔT 48.9 K, Kframe 0.968, stress 29.822 MPa.

  3. Edge allowance

    σallow = σref × edge factor × treatment factor

    Factors 1 × 3, allowance 48 MPa.