GlassFacadeLab · Solar absorption · Edge restraint
Warm-edge nighttime condition
Worked example · SI
Warn · The entered edge is warmer than the center. Review this reverse gradient separately.
Inputs
- Solar absorptance
- 0.5
- Peak solar irradiance
- 0 W/m²
- Indoor reference temperature
- 18 °C
- Shaded edge temperature
- 24 °C
- Frame shadow band
- 35 mm
- Effective heat transfer
- 15 W/(m²·K)
- Edge finish
- Clean-cut
- Glass treatment
- Annealed
- Clean-cut annealed allowance
- 18 MPa
Results
- Center–edge ΔT
- -6 K
- Edge stress
- 0 MPa
- Edge allowance
- 18 MPa
- Safety factor
- ∞
- Sunlit center temperature
- 18 °C
- Shaded edge temperature
- 24 °C
- Absorbed solar flux
- 0 W/m²
- Frame restraint assumption
- 0.792
- Edge stress utilization
- 0 %
Formula trace in SI
Absorbed heat
qsolar = α I; Tcenter = Tindoor + qsolar/heff
Absorbed 0 W/m², center 18 °C.
Edge tension
σth = E αglass max(ΔT, 0) Kframe
ΔT -6 K, Kframe 0.792, stress 0 MPa.
Edge allowance
σallow = σref × edge factor × treatment factor
Factors 1 × 1, allowance 18 MPa.