South facade with winter shadow

A wide exterior reveal shades the cold glass edge in clear winter weather.

Solar absorption · Edge restraint

Inputs

Solar and edge conditions
W/m²
°C
°C
mm
W/(m²·K)
Glass edge
MPa

Enter a verified reference when available.

Screening result

Modeled edge tension is within the entered allowance.

Pass
Center–edge ΔT
38.9K
Edge stress
22.65MPa
Edge allowance
36MPa
Safety factor
1.589
Shaded glass perimeter and center-to-edge temperaturesSolar thermal edge stress. Center–edge ΔT 38.9 K. Edge stress 22.65 MPa. Edge allowance 36 MPa. Safety factor 1.589.Sunlit center and cool perimeterAbsorptance 0.34Shaded band 75 mmCross-pane temperatureEdge -3 °C · center 35.9 °CEdgeCenterEdgeΔT 38.9 KEdge tensile demand0%100% limit200%+

Calculation details

Sunlit center temperature
35.94 °C
Shaded edge temperature
-3 °C
Absorbed solar flux
209.1 W/m²
Frame restraint assumption
0.923
Edge stress utilization
62.9 %

Formula trace in SI

  1. Absorbed heat

    qsolar = α I; Tcenter = Tindoor + qsolar/heff

    Absorbed 209.1 W/m², center 35.94 °C.

  2. Edge tension

    σth = E αglass max(ΔT, 0) Kframe

    ΔT 38.94 K, Kframe 0.923, stress 22.651 MPa.

  3. Edge allowance

    σallow = σref × edge factor × treatment factor

    Factors 1 × 2, allowance 36 MPa.