GlassFacadeLab · Solar absorption · Edge restraint
Spandrel with warm backpan
Worked example · SI
Fail · Modeled tensile stress exceeds the selected edge allowance.
Inputs
- Solar absorptance
- 0.68
- Peak solar irradiance
- 990 W/m²
- Indoor reference temperature
- 28 °C
- Shaded edge temperature
- 18 °C
- Frame shadow band
- 45 mm
- Effective heat transfer
- 10 W/(m²·K)
- Edge finish
- Clean-cut
- Glass treatment
- Heat-strengthened
- Clean-cut annealed allowance
- 18 MPa
Results
- Center–edge ΔT
- 77.3 K
- Edge stress
- 40.8 MPa
- Edge allowance
- 36 MPa
- Safety factor
- 0.882
- Sunlit center temperature
- 95.32 °C
- Shaded edge temperature
- 18 °C
- Absorbed solar flux
- 673.2 W/m²
- Frame restraint assumption
- 0.838
- Edge stress utilization
- 113.3 %
Formula trace in SI
Absorbed heat
qsolar = α I; Tcenter = Tindoor + qsolar/heff
Absorbed 673.2 W/m², center 95.32 °C.
Edge tension
σth = E αglass max(ΔT, 0) Kframe
ΔT 77.32 K, Kframe 0.838, stress 40.804 MPa.
Edge allowance
σallow = σref × edge factor × treatment factor
Factors 1 × 2, allowance 36 MPa.