GlassFacadeLab · Solar absorption · Edge restraint
South facade with winter shadow
Worked example · SI
Pass · Modeled edge tension is within the entered allowance.
Inputs
- Solar absorptance
- 0.34
- Peak solar irradiance
- 615 W/m²
- Indoor reference temperature
- 22 °C
- Shaded edge temperature
- -3 °C
- Frame shadow band
- 75 mm
- Effective heat transfer
- 15 W/(m²·K)
- Edge finish
- Clean-cut
- Glass treatment
- Heat-strengthened
- Clean-cut annealed allowance
- 18 MPa
Results
- Center–edge ΔT
- 38.9 K
- Edge stress
- 22.65 MPa
- Edge allowance
- 36 MPa
- Safety factor
- 1.589
- Sunlit center temperature
- 35.94 °C
- Shaded edge temperature
- -3 °C
- Absorbed solar flux
- 209.1 W/m²
- Frame restraint assumption
- 0.923
- Edge stress utilization
- 62.9 %
Formula trace in SI
Absorbed heat
qsolar = α I; Tcenter = Tindoor + qsolar/heff
Absorbed 209.1 W/m², center 35.94 °C.
Edge tension
σth = E αglass max(ΔT, 0) Kframe
ΔT 38.94 K, Kframe 0.923, stress 22.651 MPa.
Edge allowance
σallow = σref × edge factor × treatment factor
Factors 1 × 2, allowance 36 MPa.