Spandrel with warm backpan

An opaque insulated spandrel is represented by weak effective heat transfer from its sunlit center.

Solar absorption · Edge restraint

Inputs

Solar and edge conditions
W/m²
°C
°C
mm
W/(m²·K)
Glass edge
MPa

Enter a verified reference when available.

Screening result

Modeled tensile stress exceeds the selected edge allowance.

Fail
Center–edge ΔT
77.3K
Edge stress
40.8MPa
Edge allowance
36MPa
Safety factor
0.882
Shaded glass perimeter and center-to-edge temperaturesSolar thermal edge stress. Center–edge ΔT 77.3 K. Edge stress 40.8 MPa. Edge allowance 36 MPa. Safety factor 0.882.Sunlit center and cool perimeterAbsorptance 0.68Shaded band 45 mmCross-pane temperatureEdge 18 °C · center 95.3 °CEdgeCenterEdgeΔT 77.3 KEdge tensile demand0%100% limit200%+

Calculation details

Sunlit center temperature
95.32 °C
Shaded edge temperature
18 °C
Absorbed solar flux
673.2 W/m²
Frame restraint assumption
0.838
Edge stress utilization
113.3 %

Formula trace in SI

  1. Absorbed heat

    qsolar = α I; Tcenter = Tindoor + qsolar/heff

    Absorbed 673.2 W/m², center 95.32 °C.

  2. Edge tension

    σth = E αglass max(ΔT, 0) Kframe

    ΔT 77.32 K, Kframe 0.838, stress 40.804 MPa.

  3. Edge allowance

    σallow = σref × edge factor × treatment factor

    Factors 1 × 2, allowance 36 MPa.