Office glazing in the speech band

The facade is screened at 500 Hz with a light and a heavy pane.

Mass–air–mass · STC/OITC screening

Inputs

Double glazing
mm
mm
mm
Noise target
Hz
dB

Screening result

Current thickness ratio separates the two dip centers.

Pass
Target-band TL
42.5dB
Cavity dip
202Hz
STC estimate
40
OITC estimate
32
Double-pane section and transmission-loss spectrumGlazing acoustics. Target-band TL 42.5 dB. Cavity dip 202 Hz. STC estimate 40. OITC estimate 32.Two-pane acoustic section5 mm and 9 mm panesGap 13 mmTransmission lossModeled dB · log frequency80050 Hz10 kHzCavity dipCoincidenceTargetPredicted target-band reserve−10 dBTarget+10 dB

Calculation details

Combined glass surface mass
35 kg/m²
Mass-law loss at target band
37.9 dB
Pane 1 coincidence frequency
2392 Hz
Pane 2 coincidence frequency
1329 Hz
Target-band reserve
4.5 dB
Thick-to-thin pane ratio
1.8
Pane asymmetry
Current thickness ratio separates the two dip centers.

Formula trace in SI

  1. Mass law

    TLmass = 20 log₁₀[(m₁ + m₂) f] − 47

    35 kg/m² at 500 Hz → 37.9 dB.

  2. Resonant frequencies

    fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)

    Cavity 202 Hz, glass 2392 Hz and 1329 Hz.

  3. Target band

    TLscreen = TLmass + cavity gain − resonance and coincidence penalties

    Predicted 42.5 dB, reserve 4.5 dB.

  4. Screening classes

    Speech contour fit and A-weighted outdoor spectrum energy loss

    STC estimate 40, OITC estimate 32 from the synthetic spectrum.