GlassFacadeLab · Mass–air–mass · STC/OITC screening
Office glazing in the speech band
Worked example · SI
Pass · Current thickness ratio separates the two dip centers.
Inputs
- Pane 1 thickness
- 5 mm
- Pane 2 thickness
- 9 mm
- Air or gas cavity
- 13 mm
- Cavity gas
- Argon
- Laminated damping
- Unlaminated baseline
- Target band center
- 500 Hz
- Target transmission loss
- 38 dB
Results
- Target-band TL
- 42.5 dB
- Cavity dip
- 202 Hz
- STC estimate
- 40
- OITC estimate
- 32
- Combined glass surface mass
- 35 kg/m²
- Mass-law loss at target band
- 37.9 dB
- Pane 1 coincidence frequency
- 2392 Hz
- Pane 2 coincidence frequency
- 1329 Hz
- Target-band reserve
- 4.5 dB
- Thick-to-thin pane ratio
- 1.8
Formula trace in SI
Mass law
TLmass = 20 log₁₀[(m₁ + m₂) f] − 47
35 kg/m² at 500 Hz → 37.9 dB.
Resonant frequencies
fmam = √[(K/d)(1/m₁ + 1/m₂)]/(2π); fc = c²√(m/D)/(2π)
Cavity 202 Hz, glass 2392 Hz and 1329 Hz.
Target band
TLscreen = TLmass + cavity gain − resonance and coincidence penalties
Predicted 42.5 dB, reserve 4.5 dB.
Screening classes
Speech contour fit and A-weighted outdoor spectrum energy loss
STC estimate 40, OITC estimate 32 from the synthetic spectrum.