Skylight verge with eighth-point blocks

Framing constraints move the blocks toward the glass corners.

GANA setting-block screen

Inputs

Slope, glass and loading
°
m
m
mm
kg/m³
kPa
kPa

Positive presses toward the frame.

Setting blocks
mm
Shore A
%

25% places blocks at the quarter points.

MPa

Use the block manufacturer’s allowable pressure.

Screening result

The block hardness is outside the 80–90 Shore A screening range.

Warn
Normal load
0.69kPa
In-plane force
1345N
Min. block
101.6mm
Block bearing
0.433MPa
Sloped-glass free-body diagram and setting blocksSkylight snow and blocks. Normal load 0.69 kPa. In-plane force 1345 N. Min. block 101.6 mm. Block bearing 0.433 MPa.Sloped glass load components48 ° from horizontalWeightNormalThrustLower edge block placementBlock length 115 mm12.5 % from each cornerGoverning block demand0%100% limit200%+

Calculation details

Total glass weight
818.718 N
Total glass mass
83.486 kg
Dead load per glass area
0.331 kPa
Snow resultant per glass area
0.401 kPa
Glass-only downslope thrust
608.426 N
Gravity and snow thrust per block
672.683 N
Minimum block width (glass + 1/8 in)
16.695 mm
Clearance from corner to block end
105 mm

Formula trace in SI

  1. Weight and snow basis

    W = ρ t A g; p_snow = p_roof cos θ for plan-area pressure

    W = 818.718 N, converted p_snow = 0.401 kPa.

  2. Slope components

    qn = (pd + ps) cos θ + pw; F∥ = (pd + ps) A sin θ

    Angle 48 °, qn = 0.69 kPa, F∥ = 1345.367 N.

  3. Block length

    ℓmin = max(4 in, 0.1 in × area in ft²)

    Per-block minimum 101.6 mm, provided 115 mm.

  4. Edge bearing

    pblock = F∥ / (2 ℓblock tglass)

    0.433 MPa versus 0.85 MPa allowance.