GlassFacadeLab · Solar absorption · Edge restraint
West-facing tinted storefront
Worked example · SI
Fail · Modeled tensile stress exceeds the selected edge allowance.
Inputs
- Solar absorptance
- 0.64
- Peak solar irradiance
- 900 W/m²
- Indoor reference temperature
- 25 °C
- Shaded edge temperature
- 15 °C
- Frame shadow band
- 52 mm
- Effective heat transfer
- 15 W/(m²·K)
- Edge finish
- Seamed
- Glass treatment
- Annealed
- Clean-cut annealed allowance
- 18 MPa
Results
- Center–edge ΔT
- 48.4 K
- Edge stress
- 26.34 MPa
- Edge allowance
- 15.3 MPa
- Safety factor
- 0.581
- Sunlit center temperature
- 63.4 °C
- Shaded edge temperature
- 15 °C
- Absorbed solar flux
- 576 W/m²
- Frame restraint assumption
- 0.864
- Edge stress utilization
- 172.1 %
Formula trace in SI
Absorbed heat
qsolar = α I; Tcenter = Tindoor + qsolar/heff
Absorbed 576 W/m², center 63.4 °C.
Edge tension
σth = E αglass max(ΔT, 0) Kframe
ΔT 48.4 K, Kframe 0.864, stress 26.337 MPa.
Edge allowance
σallow = σref × edge factor × treatment factor
Factors 0.85 × 1, allowance 15.3 MPa.