Kern shell-side crossflow & pressure drop
Screen shell-side crossflow area, heat transfer coefficient, and pressure drop for a segmental-baffle bundle.
Segmental baffle cutaway
Aₛ = DₛB(p − Dₒ)/p · Nu = 0.36 Re⁰·⁵⁵ Pr¹ᐟ³ (μ/μwall)⁰·¹⁴
- Crossflow area
- 0.03808m²
- Shell velocity
- 1.1817m/s
- Shell hₒ
- 6,981.6W/(m²·K)
- Shell ΔP
- 166.91kPa
- Within the displayed screening checks.
Inputs
Calculated results
- Bundle crossflow area
- 0.03808 m²
- Crossflow velocity
- 1.1817 m/s
- Shell-side film hₒ
- 6,981.6 W/(m²·K)
- Shell-side pressure drop
- 166.91 kPa
- Equivalent diameter
- 13.771 mm
- Shell Reynolds number
- 22,377
- Gross baffle window
- 0.071 m²
- Estimated segmental baffles
- 18
- Crossflow sections
- 19
- Shell mass flux
- 1,169.9 kg/(m²·s)
- Prandtl number
- 4.8542
- Kern friction factor
- 0.26527
- Baffle spacing / shell ID
- 0.41176
- Screening minimum spacing
- 0.136 m
Calculation basis
Kern crossflow area uses the notional tube row at the shell equator. Equivalent diameter comes from the open area and wetted perimeter of a square or triangular pitch cell.
The 25% nominal baffle-cut correlation estimates shell-side hₒ and pressure drop. The entered cut changes the gross segment window and diagram. Leakage, bypass, window obstructions, and nozzle losses require a more detailed method.
The spacing screen runs from the larger of 0.2Dₛ and 50 mm to Dₛ. Maximum unsupported length and vibration depend on the actual tube material and layout.
Methodology and references