HeatExchangerLab

1–2 exchanger for amine cooling

A one-shell, two-tube-pass cooler removes heat from an amine circulation loop using cooling water.

Terminal temperature profile

Q = U × A × Fₜ × ΔTₗₘ

Edit inputs ↓
Area needed
46.61m²
LMTD
54.425K
Fₜ factor
0.9566
Rated duty
1,034.7kW
Terminal temperature profile110 °C79 °C52 °C28 °CHOT STREAM →← COLD STREAMEnd AEnd BFₜ 00.75 screenFₜ 1
The lines join terminal temperatures along the hot-stream direction. Shell cases use a counterflow reference for the temperature plot.
  • Within the displayed screening checks.

Inputs

°C
°C
°C
°C
kW
W/(m²·K)
m²

Calculated results

Required surface
46.61 m²
Log mean ΔT
54.425 K
Correction factor Fₜ
0.9566
Available duty
1,034.7 kW
Target duty
910 kW
Corrected mean ΔT
52.063 K
Terminal difference A
58 K
Terminal difference B
51 K
Cold temperature ratio P
0.29268
Stream temperature ratio R
1.2917
Duty reserve vs. target
13.709 %

Worked solution

Preset calculation · Metric SI

  1. Pair the terminal temperatures to obtain 58 K and 51 K. Their log mean is 54.425 K.
  2. Use P = 0.29268 and R = 1.2917 for the shell correction where applicable. Fₜ = 0.9566.
  3. Divide 910 kW by 375 W/(m²·K) times the corrected drive of 52.063 K to obtain 46.61 m².

Compare the corrected temperature drive with the reference counterflow mean. Read the available-duty reserve for the installed surface.

Calculation basis

Enter four terminal temperatures, a target duty, and a service U. Required surface meets the target duty at the specified conditions. Available duty rates the entered surface at those same conditions.

The two terminal differences define ΔTₗₘ. Equal terminal differences give that exact difference. Parallel and counterflow use Fₜ = 1 with their own terminal pairing.

For ideal 1–2 and 2–4 shell arrangements, Fₜ corrects the counterflow mean using Bowman–Mueller–Nagle P and R. Fₜ below 0.75 warrants a layout review. Terminal temperatures must also lie inside the feasible Fₜ domain.