1–2 exchanger for amine cooling
A one-shell, two-tube-pass cooler removes heat from an amine circulation loop using cooling water.
Terminal temperature profile
Q = U × A × Fₜ × ΔTₗₘ
- Area needed
- 46.61m²
- LMTD
- 54.425K
- Fₜ factor
- 0.9566
- Rated duty
- 1,034.7kW
- Within the displayed screening checks.
Inputs
Calculated results
- Required surface
- 46.61 m²
- Log mean ΔT
- 54.425 K
- Correction factor Fₜ
- 0.9566
- Available duty
- 1,034.7 kW
- Target duty
- 910 kW
- Corrected mean ΔT
- 52.063 K
- Terminal difference A
- 58 K
- Terminal difference B
- 51 K
- Cold temperature ratio P
- 0.29268
- Stream temperature ratio R
- 1.2917
- Duty reserve vs. target
- 13.709 %
Worked solution
Preset calculation · Metric SI
- Pair the terminal temperatures to obtain 58 K and 51 K. Their log mean is 54.425 K.
- Use P = 0.29268 and R = 1.2917 for the shell correction where applicable. Fₜ = 0.9566.
- Divide 910 kW by 375 W/(m²·K) times the corrected drive of 52.063 K to obtain 46.61 m².
Compare the corrected temperature drive with the reference counterflow mean. Read the available-duty reserve for the installed surface.
Calculation basis
Enter four terminal temperatures, a target duty, and a service U. Required surface meets the target duty at the specified conditions. Available duty rates the entered surface at those same conditions.
The two terminal differences define ΔTₗₘ. Equal terminal differences give that exact difference. Parallel and counterflow use Fₜ = 1 with their own terminal pairing.
For ideal 1–2 and 2–4 shell arrangements, Fₜ corrects the counterflow mean using Bowman–Mueller–Nagle P and R. Fₜ below 0.75 warrants a layout review. Terminal temperatures must also lie inside the feasible Fₜ domain.