Cold-Climate Heat Pump Economic Balance Point
Find the temperature where a cold-climate heat pump and a gas furnace cost the same using fuel rates and COP at 5°F and 47°F.
Inputs
Results ↓Results
Example estimate- Seasonal heat pump COP
- 2.85 COP
- Selected comparison
- Natural gas
- Annual savings vs. comparison
- $193.18 / year
- Simple payback
- 15.5 years
- Break-even COP
- 2.36 COP
- Economic balance point
- 18.2 °F
| Energy source | Per MMBtu | Annual |
|---|---|---|
| Heat pump | $14.4 | $935.77 |
| Natural gas | $17.37 | $1,128.95 |
| Propane | $32.09 | $2,085.91 |
| Heating oil | $31 | $2,015.29 |
| Electric resistance | $41.03 | $2,666.95 |
Calculation inputs
- Annual heat delivered indoors
- 65 MMBtu
- Seasonal efficiency source
- Seasonal COP
- Seasonal COP
- 2.85
- Operating COP at 47°F
- 3.7
- Operating COP at 5°F
- 1.75
- Backup fuel for comparison
- Natural gas
- Added heat pump installation cost
- 3000 $
- Electricity price
- 0.14 $/kWh
- Natural gas price
- 1.65 $/therm
- Gas furnace AFUE
- 95 %
- Propane price
- 2.7 $/gal
- Propane furnace AFUE
- 92 %
- Heating oil price
- 3.65 $/gal
- Oil furnace AFUE
- 85 %
Worked example
The gas furnace’s cost per delivered MMBtu sets the comparison COP. The outdoor point is where the line between 5°F and 47°F intersects that COP. Change the electric rate to see the switching temperature move.
Annual heat pump energy cost $935.77 / year
What to check next
Overlay the outdoor unit’s heat output and the building load separately. Use the more restrictive result when evaluating a changeover setting.
Formulas and assumptions
- Delivered heat cost
- Cost per MMBtu = price per unit × 1,000,000 ÷ (BTU per unit × efficiency). Seasonal COP can be estimated with HSPF2 ÷ 3.412.
- Economic balance point
- Break-even COP = electric resistance cost per MMBtu ÷ backup heat cost per MMBtu. Interpolate between the entered 5°F and 47°F COP values.
- Simple payback
- Annual energy cost = delivered heat cost × annual load. Payback = positive added installation cost ÷ positive annual savings.
Frequently asked questions
What does a null economic crossover temperature mean?
One option can be cheaper throughout the entered temperature range, or the costs can tie across the range. The tool shows that condition instead of extrapolating.
How often should I recalculate a dual-fuel price changeover?
Update it when marginal gas or electric rates change and after an equipment replacement. Seasonal electric tariffs can justify checking several scenarios.