HSPF2 to Seasonal COP and Heating Cost

Convert an HSPF2 rating of 9.2 to a seasonal COP estimate and see how it changes an annual heat-pump bill.

Heat demand and heat pump

Heat pump quote minus the selected alternative, after applicable incentives.

Energy rates and furnace efficiencies

Results

Example estimate
Annual heat pump energy cost$886.96 / year
Heat pump $887 Natural gas $935 Propane $1,540 Heating oil $1,488 Electric resistance $2,391
Annual energy cost for the same amount of delivered heat.
Seasonal heat pump COP
2.7 COP
Selected comparison
Natural gas
Annual savings vs. comparison
$47.78 / year
Simple payback
62.8 years
Break-even COP
2.56 COP
Economic balance point
19.9 °F
Cost by heat source
Energy sourcePer MMBtuAnnual
Heat pump$18.48$886.96
Natural gas$19.47$934.74
Propane$32.09$1,540.37
Heating oil$31$1,488.21
Electric resistance$49.82$2,391.46
  • HSPF2 gives a test-season COP proxy. Local weather, defrost and auxiliary heat can change the annual result.

Worked example

HSPF2 expresses standardized seasonal heating output in BTU per Wh. Dividing by about 3.412 converts to a test-season ratio in the same energy units, which can be used for a first bill estimate.

Annual heat pump energy cost $886.96 / year

What to check next

Use cold-weather performance and backup operation when refining the estimate. A rating conversion cannot account for a specific home’s outdoor-temperature hours.

Formulas and assumptions

Delivered heat cost
Cost per MMBtu = price per unit × 1,000,000 ÷ (BTU per unit × efficiency). Seasonal COP can be estimated with HSPF2 ÷ 3.412.
Economic balance point
Break-even COP = electric resistance cost per MMBtu ÷ backup heat cost per MMBtu. Interpolate between the entered 5°F and 47°F COP values.
Simple payback
Annual energy cost = delivered heat cost × annual load. Payback = positive added installation cost ÷ positive annual savings.

Frequently asked questions

Is a 9.2 HSPF2 rating the same as COP 9.2?

HSPF2 uses BTU per watt-hour. Dividing 9.2 by about 3.412 gives a seasonal COP proxy of roughly 2.7.

When should I enter measured seasonal COP instead of HSPF2?

Use a measured or proposed seasonal COP when it reflects similar weather, installation and backup heat. Keep 5°F and 47°F point efficiencies separate.

More sizing examples

Open the general heat pump vs. furnace calculator