Heat Pump vs. Electric Baseboard Cost
Compare a heat pump with electric resistance baseboards at the same kWh rate, using 40 MMBtu of annual delivered space heat.
Inputs
Results ↓Results
Example estimateAnnual heat pump energy cost$848.9 / year
- Seasonal heat pump COP
- 2.9 COP
- Selected comparison
- Electric resistance
- Annual savings vs. comparison
- $1,612.9 / year
- Simple payback
- 3.4 years
- Break-even COP
- 1 COP
- Economic balance point
- Heat pump costs less from 5–47°F
| Energy source | Per MMBtu | Annual |
|---|---|---|
| Heat pump | $21.22 | $848.9 |
| Natural gas | $14.74 | $589.47 |
| Propane | $32.09 | $1,283.64 |
| Heating oil | $31 | $1,240.18 |
| Electric resistance | $61.54 | $2,461.8 |
Calculation inputs
- Annual heat delivered indoors
- 40 MMBtu
- Seasonal efficiency source
- Seasonal COP
- Seasonal COP
- 2.9
- Operating COP at 47°F
- 3.4
- Operating COP at 5°F
- 1.6
- Backup fuel for comparison
- Electric resistance
- Added heat pump installation cost
- 5500 $
- Electricity price
- 0.21 $/kWh
- Natural gas price
- 1.4 $/therm
- Gas furnace AFUE
- 95 %
- Propane price
- 2.7 $/gal
- Propane furnace AFUE
- 92 %
- Heating oil price
- 3.65 $/gal
- Oil furnace AFUE
- 85 %
Worked example
Electric baseboard resistance heat is modeled at COP 1 at the point of use. The heat pump uses fewer purchased kWh at seasonal COP 2.9 for the same annual delivered load.
Annual heat pump energy cost $848.9 / year
What to check next
If baseboards remain as backup, estimate what share of heat they deliver in practice. Adjust the effective seasonal COP before comparing the budget.
Formulas and assumptions
- Delivered heat cost
- Cost per MMBtu = price per unit × 1,000,000 ÷ (BTU per unit × efficiency). Seasonal COP can be estimated with HSPF2 ÷ 3.412.
- Economic balance point
- Break-even COP = electric resistance cost per MMBtu ÷ backup heat cost per MMBtu. Interpolate between the entered 5°F and 47°F COP values.
- Simple payback
- Annual energy cost = delivered heat cost × annual load. Payback = positive added installation cost ÷ positive annual savings.
Frequently asked questions
What operating COP makes a heat pump tie electric resistance?
At the same electric price, COP 1 is the break-even operating point. Any higher COP uses less purchased electricity for the same heat.
How should I estimate savings if the heat pump serves only the living room?
Enter the load the heat pump can actually replace. Keep baseboard energy for the rest of the house in the overall budget.