Worked example

A 4 ft block stack that triggers geogrid review

A 16 ft wall proposes 36 in exposed and 12 in buried, with 8 in course units. Use the estimate to list materials for a design review.

Project inputs

Wall size and units
ft
in
in
in
in
in
%
in
Drainage detail
in
lb/ft³
ft
in

Material & layout estimate

Wall blocks to buy

76
Cap units to buy
17
Block courses
6
Full block stack height
48 in
Block face area per unit
0.8889 ft²
Drainage gravel volume
2.37 yd³
Drainage gravel weight
3.04 US tons
Perforated pipe along wall
16 ft
Solid outlet extension
6 ft
Geotextile with lap
112 ft²
Total batter setback
3.75 in

Get a site-specific wall design and geogrid review. This estimate flags a stack of 4 ft or more or a surcharge or backslope. Check manufacturer limits and local requirements.

Gravel is the gross drainage column behind the blocks. Add separate material for hollow cores and the leveling pad as needed.

Wall batter & drainage section Schematic
Wall batter & drainage sectionWall blocks to buy: 76. Cap units to buy: 17. Block courses: 6. Full block stack height: 48 in BLOCK / BACKFILL36 in exposedWALL TAKEOFF6 full courses48 in stack height3.75 in total setback12 in drainage column2.37 yd³ drainage gravelGet a design review

Starting estimate

The 48 in stack triggers the review alert, including the buried section. The calculator estimates quantities for the wall and its drainage envelope.

Wall blocks to buy
76
Full block stack height
48 in
Total batter setback
3.75 in

How the estimate works

  1. Add the exposed and buried heights, then round up to full block courses. Divide the run into whole block positions and add the selected allowance to blocks and caps.
  2. Use the rounded block-stack height for the rectangular drainage gravel envelope. Estimate the fabric from the rear face, top, bottom, and one longitudinal lap.
  3. Use one perforated pipe run along the wall and the entered solid outlet extension. Total batter is one setback for each course above the first.

Questions and answers

Why does a 36 in exposed wall trigger the four-foot screening alert?

The screen uses the full rounded block stack. Adding 12 in of embedment to 36 in exposed gives 48 in.

Can the setback shown here replace engineered geogrid sizing?

Use the wall designer’s reinforcement schedule. The setback row only adds up the chosen setback per course.