Worked example

Pipe and fabric behind a 45 ft wall

Price a 45 ft perforated run and a 14 ft solid outlet extension. The 30 in block stack uses a 12 in gravel envelope and an 18 in fabric lap.

Project inputs

Wall size and units
ft
in
in
in
in
in
%
in
Drainage detail
in
lb/ft³
ft
in

Material & layout estimate

Wall blocks to buy

158
Cap units to buy
48
Block courses
5
Full block stack height
30 in
Block face area per unit
0.75 ft²
Drainage gravel volume
4.17 yd³
Drainage gravel weight
5.34 US tons
Perforated pipe along wall
45 ft
Solid outlet extension
14 ft
Geotextile with lap
270 ft²
Total batter setback
3 in

Check geogrid, embedment, soil, and outlet details against the selected wall system. Lower walls can require reinforcement too.

Gravel is the gross drainage column behind the blocks. Add separate material for hollow cores and the leveling pad as needed.

Wall batter & drainage section Schematic
Wall batter & drainage sectionWall blocks to buy: 158. Cap units to buy: 48. Block courses: 5. Full block stack height: 30 in BLOCK / BACKFILL22 in exposedWALL TAKEOFF5 full courses30 in stack height3 in total setback12 in drainage column4.17 yd³ drainage gravelCheck system details

Starting estimate

The fabric model takes 6 ft of cut width for each foot of wall. Compare the 270 ft² result with roll widths and separate overlaps.

Wall blocks to buy
158
Perforated pipe along wall
45 ft
Solid outlet extension
14 ft
Geotextile with lap
270 ft²

How the estimate works

  1. Add the exposed and buried heights, then round up to full block courses. Divide the run into whole block positions and add the selected allowance to blocks and caps.
  2. Use the rounded block-stack height for the rectangular drainage gravel envelope. Estimate the fabric from the rear face, top, bottom, and one longitudinal lap.
  3. Use one perforated pipe run along the wall and the entered solid outlet extension. Total batter is one setback for each course above the first.

Questions and answers

How does the 14 ft solid outlet change this retaining wall order?

It adds 14 ft of solid pipe outside the 45 ft perforated wall run. Include fittings, cleanouts, and the approved discharge detail separately.

Why does the wall fabric estimate use a 6 ft cut width?

It adds 30 in of rear face, 12 in top, 12 in bottom, and an 18 in lap, for 72 in of fabric width.