Worked example

Small block and cap count for a 20 ft garden edge

A 20 ft edge uses 8 in wide by 4 in high faces, 10 in cap modules, and an 8% allowance. Stack 20 in exposed plus 4 in buried.

Project inputs

Wall size and units
ft
in
in
in
in
in
%
in
Drainage detail
in
lb/ft³
ft
in

Material & layout estimate

Wall blocks to buy

195
Cap units to buy
26
Block courses
6
Full block stack height
24 in
Block face area per unit
0.2222 ft²
Drainage gravel volume
1.48 yd³
Drainage gravel weight
1.9 US tons
Perforated pipe along wall
20 ft
Solid outlet extension
6 ft
Geotextile with lap
100 ft²
Total batter setback
3.75 in

Check geogrid, embedment, soil, and outlet details against the selected wall system. Lower walls can require reinforcement too.

Gravel is the gross drainage column behind the blocks. Add separate material for hollow cores and the leveling pad as needed.

Wall batter & drainage section Schematic
Wall batter & drainage sectionWall blocks to buy: 195. Cap units to buy: 26. Block courses: 6. Full block stack height: 24 in BLOCK / BACKFILL20 in exposedWALL TAKEOFF6 full courses24 in stack height3.75 in total setback12 in drainage column1.48 yd³ drainage gravelCheck system details

Starting estimate

The 20 ft run takes 30 block positions per course and 24 cap positions before allowance. Keep the two module lengths separate on the order.

Wall blocks to buy
195
Cap units to buy
26
Block courses
6

How the estimate works

  1. Add the exposed and buried heights, then round up to full block courses. Divide the run into whole block positions and add the selected allowance to blocks and caps.
  2. Use the rounded block-stack height for the rectangular drainage gravel envelope. Estimate the fabric from the rear face, top, bottom, and one longitudinal lap.
  3. Use one perforated pipe run along the wall and the entered solid outlet extension. Total batter is one setback for each course above the first.

Questions and answers

Why do the caps use a different count from one small-block course?

The cap module is 10 in long while the block module is 8 in. The same run fits fewer cap positions.

Can I leave out the allowance if the 20 ft edge fits whole modules?

Zero is editable. Allow for breakage, cuts for staggered seams, and matching replacements when those matter.